• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Relation between the size of lesions and arrhythmias produced by microwave catheter ablation with a special electrode device.

作者信息

Ikeda T, Sugi K, Enjoji Y, Kasao M, Abe R, Ninomiya K, Yabuki S, Yamaguchi T

机构信息

Third Department of Internal Medicine, Ohashi Hospital, Toho University School of Medicine, Tokyo, Japan.

出版信息

Jpn Circ J. 1994 Mar;58(3):214-21. doi: 10.1253/jcj.58.214.

DOI:10.1253/jcj.58.214
PMID:8015148
Abstract

The purpose of this study was to examine the effects of microwave catheter ablation of ventricular myocardium. Microwave energy with a frequency of 2450 MHz was delivered via a coaxial catheter with an electrode ball tip. Microwave energy was applied to canine isolated left ventricular endocardium in vitro and to 6 anesthetized dogs in vivo at 50 watts for 15-150 sec. Ventricular arrhythmia was not observed during ablation in any of the dogs when microwave energy was applied for less than 45 sec. When the duration of microwave ablation was greater than 45 sec, ventricular premature contractions were observed in all of the dogs. Nonsustained ventricular tachycardia developed when the duration of microwave delivery was greater than 90 sec. After the cessation of ablation, ventricular arrhythmias did not occur and ventricular programmed stimulation did not induce ventricular tachycardia in any of the dogs. Except for ventricular arrhythmia, no declines in the hemodynamic status were observed in any of the 6 dogs. The size of the ablated lesion was significantly greater as the duration of ablation was increased (p < 0.05). When ablation lasted for more than 120 sec, the coagulation layer was extended to the epicardium in all 6 dogs. The results of this study suggest that microwave ablation is feasible for the treatment of tachyarrhythmias from deep focus of ventricular myocardium with relatively small proarrhythmic effects.

摘要

相似文献

1
Relation between the size of lesions and arrhythmias produced by microwave catheter ablation with a special electrode device.
Jpn Circ J. 1994 Mar;58(3):214-21. doi: 10.1253/jcj.58.214.
2
[An experimental study of catheter ablation using microwave energy via coaxial electrode catheter].
Kokyu To Junkan. 1993 Oct;41(10):981-5.
3
Microwave ablation of the atrioventricular junction in vivo and ventricular myocardium in vitro and in vivo. Effects of varying power and duration on lesion volume.
Jpn Heart J. 1994 Mar;35(2):175-91. doi: 10.1536/ihj.35.175.
4
Catheter microwave ablation therapy for cardiac arrhythmias.导管微波消融治疗心律失常。
Bioelectromagnetics. 1999;Suppl 4:120-32. doi: 10.1002/(sici)1521-186x(1999)20:4+<120::aid-bem14>3.3.co;2-0.
5
Optimal frequency of radiofrequency catheter ablation in vitro and in vivo for treating ventricular tachycardias--a study using various frequencies.
Jpn Circ J. 1993 Sep;57(9):921-7. doi: 10.1253/jcj.57.921.
6
[An experimental study of determining the appropriate frequency of radiofrequency catheter ablation in vitro and in vivo for ventricular tachycardias].[体外及体内确定室性心动过速射频导管消融合适频率的实验研究]
Kokyu To Junkan. 1992 Oct;40(10):975-80.
7
Safety and efficacy of a steerable temperature monitoring microwave catheter system for ventricular myocardial ablation.
J Cardiovasc Electrophysiol. 2000 Mar;11(3):305-10. doi: 10.1111/j.1540-8167.2000.tb01799.x.
8
Advanced radiofrequency catheter ablation in canine myocardium.犬心肌组织中的高级射频导管消融术。
Am Heart J. 1994 Apr;127(4 Pt 1):851-7. doi: 10.1016/0002-8703(94)90553-3.
9
Microwave ablation of canine atrial tachycardia induced by aconitine.乌头碱诱发犬房性心动过速的微波消融
Am Heart J. 1995 May;129(5):1021-5. doi: 10.1016/0002-8703(95)90126-4.
10
Cooled-tip ablation results in increased radiofrequency power delivery and lesion size in the canine heart: importance of catheter-tip temperature monitoring for prevention of popping and impedance rise.冷尖端消融可增加犬心脏的射频能量传递及损伤灶大小:导管尖端温度监测对预防“弹出”和阻抗升高的重要性
J Interv Card Electrophysiol. 2002 Feb;6(1):9-16. doi: 10.1023/a:1014140104777.

引用本文的文献

1
Alternate energy sources for catheter ablation.
Curr Cardiol Rep. 1999 Jul;1(2):165-71. doi: 10.1007/s11886-999-0076-y.