Short- and long-term reproducibility of QT, QTc, and QT dispersion measurement in healthy subjects.

作者信息

Kautzner J, Yi G, Camm A J, Malik M

机构信息

Department of Cardiological Sciences, St. George's Hospital Medical School, London, England.

出版信息

Pacing Clin Electrophysiol. 1994 May;17(5 Pt 1):928-37. doi: 10.1111/j.1540-8159.1994.tb01435.x.

Abstract

The study investigated interobserver and intrasubject reproducibility of QT interval duration and dispersion measured in standard 12-lead ECGs recorded at 25 mm/sec. Twenty-eight healthy volunteers were studied. Each underwent four ECG recordings, which were performed 1, 7, and 30 days apart. Two independent observers analyzed each ECG record. In each lead with a distinguishable T wave pattern, the RR interval, Q-peak of T interval, and Q-end of T interval were measured using a digitizing board with a 0.1-mm resolution. From each recording the following measures were derived: the maximum, minimum, and mean QT interval; maximum, minimum, and mean heart rate corrected QT interval (QTc); QT and QTc dispersion (the difference between the maximum and minimum QT interval among the 12 leads); and adjusted QT and QTc dispersion (dispersion divided by the square root of the number of leads measured). The interobserver and short-term (1 day) and long-term (1 week and 1 month) reproducibility of individual indices was assessed by computing the relative errors and comparing them by a standard sign test. In addition, the distributions of maximum and minimum QTc values among electrocardiographic leads, and the differences between QT-end and QT-peak based measurements were investigated. The results showed that: (1) the measurement of the QT interval from standard ECG recordings is feasible and not operator dependent (interobserver relative error < 4%); (2) the duration of the QT interval in healthy volunteers is stable and its short- and long-term reproducibility is high (intrasubject relative error < 6%); (3) parameters that characterize dispersion of the QT interval in the 12-lead ECG are highly nonreproducible, both between subsequent recording (relative error of 25%-35%) and between observers (relative error 28%-33%), the reproducibility of QT dispersion is significantly lower than that of QT duration (P < 0.01); and (4) the duration of the entire QT interval correlates only weakly with the duration of the Q-peak of T interval.

摘要

该研究调查了在以25毫米/秒记录的标准12导联心电图中测量的QT间期时长及离散度的观察者间和受试者内重复性。对28名健康志愿者进行了研究。每位志愿者接受了4次心电图记录,记录时间间隔分别为1天、7天和30天。两名独立观察者分析每份心电图记录。在每个具有可分辨T波形态的导联中,使用分辨率为0.1毫米的数字化板测量RR间期、T间期的Q峰和T间期的Q末。从每次记录中得出以下测量值:最大、最小和平均QT间期;最大、最小和平均心率校正QT间期(QTc);QT和QTc离散度(12导联中最大和最小QT间期之间的差值);以及校正后的QT和QTc离散度(离散度除以测量导联数的平方根)。通过计算相对误差并采用标准符号检验进行比较,评估了各指标的观察者间以及短期(1天)和长期(1周和1个月)重复性。此外,还研究了心电图导联中最大和最小QTc值的分布,以及基于T间期终点和T间期峰值测量的差异。结果表明:(1)从标准心电图记录中测量QT间期是可行的,且不依赖于操作者(观察者间相对误差<4%);(2)健康志愿者的QT间期时长稳定,其短期和长期重复性高(受试者内相对误差<6%);(3)表征12导联心电图中QT间期离散度的参数在后续记录之间(相对误差为25%-35%)以及观察者之间(相对误差为28%-33%)的重复性都很低,QT离散度的重复性显著低于QT时长(P<0.01);(4)整个QT间期的时长与T间期Q峰的时长仅存在微弱关联。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验