In the paper the changes appearing in in vitro during perfusion of citrated blood through a column filled with Vinylsorb SS in temperature of 22 and 37 degrees C were evaluated. In both temperatures there was a slight decrease of the number of leucocytes and thrombocytes, both in the examined and the control system. The remaining number of thrombocytes ensured hemostasia. The authors think that the main factor causing decrease of the number of morphotic elements of blood as well as activating slightly coagulation system was the effect of drains, a peristaltic pump, blood container and perfusion column and not the sorbent. Vinylsorb turned out to be a good and safe sorbent which should be applied in the process of hemoperfusion in people.
本文评估了在22摄氏度和37摄氏度下,枸橼酸盐血通过填充有乙烯基吸附剂SS的柱体进行体外灌注时所出现的变化。在这两个温度下,无论是检测系统还是对照系统,白细胞和血小板数量均略有下降。剩余的血小板数量确保了止血。作者认为,导致血液形态学成分数量减少以及轻微激活凝血系统的主要因素是引流管、蠕动泵、血容器和灌注柱的作用,而非吸附剂。结果表明,乙烯基吸附剂是一种良好且安全的吸附剂,应应用于人体血液灌注过程中。