Lax K G, Okin P M, Kligfield P
Department of Medicine, New York Hospital-Cornell Medical Center, New York 10021.
Am Heart J. 1994 Aug;128(2):271-80. doi: 10.1016/0002-8703(94)90479-0.
Normal values for simple and rate-corrected measures of the duration and dispersion of electrocardiographic (ECG) repolarization during treadmill exercise were obtained in 94 clinically normal men, and the behavior of these measures during ischemia was examined in 79 men with catheterization-proven disease or with stable angina, all of whom had normal resting ECGs. Temporal measures of repolarization, exemplified by QTc, were found to be moderately sensitive for disease only when highly specific criteria were derived from data at peak exercise heart rates that were significantly higher in normal subjects than in patients; sensitivities of rate-corrected measures declined markedly when criteria were derived from matched heart rate data in normal subjects. In contrast, the standard deviation of the mean measured J-point to T-wave peaks across the V1 to V6 precordial leads (SD-SoTm), a measure of precordial dispersion of repolarization, was unrelated to exercise heart rate in normal subjects; SD-SoTm exceeding the 95% value at matched intraexercise heart rates in normal subjects was found at peak exercise in 38% of men with coronary disease, including some patients with otherwise false-negative standard exercise test responses.
在94名临床正常男性中获得了跑步机运动期间心电图(ECG)复极持续时间和离散度的简单及心率校正测量的正常值,并在79名经导管检查证实患有疾病或患有稳定型心绞痛的男性中检查了这些测量在缺血期间的变化情况,所有这些男性静息心电图均正常。以QTc为例的复极时间测量方法,只有当从运动高峰心率数据得出高度特异性标准时,才发现对疾病具有中等敏感性,而正常受试者的运动高峰心率明显高于患者;当从正常受试者的匹配心率数据得出标准时,心率校正测量方法的敏感性显著下降。相比之下,胸前导联V1至V6平均测量的J点至T波峰值的标准差(SD-SoTm),即复极胸前离散度的测量指标,在正常受试者中与运动心率无关;在38%的冠心病男性患者运动高峰时发现SD-SoTm超过正常受试者运动中匹配心率时的95%值,其中包括一些标准运动试验反应为假阴性的患者。