Abstract

The occurrence of antibodies against antigens prepared from strains representing 13 O groups of Pseudomonas aeruginosa and against a polyvalent Ps. aeruginosa antigen (St-Ag) has been investigated in sera from 100 patients. By means of fused rocket immunoelectrophoresis with intermediate gel it was found that the humoral immune response against Ps. aeruginosa resulting in precipitating antibodies will be detected by St-Ag as well as by any other of the antigen samples investigated. Six of the sera contained group-specific antibodies which were revealed by only one of the antigen samples used and not by St-Ag. These six sera were further studied by means of various quantitative immunoelectrophoretic methods using St-Ag as well as antigens prepared from the infecting Ps. aeruginosa strain in the patient concerned. In all six sera, only one extra precipitin could be detected using antigens prepared from the homologous strain instead of St-Ag. This extra precipitin corresponded presumably to group-specific O-antigens not included in St-Ag. In sera from patients, these group-specific antibodies were always accompanied by antibodies against antigens common to all strains of Ps. aeruginosa.

摘要

对100例患者血清中抗源自代表铜绿假单胞菌13个O群菌株的抗原以及抗多价铜绿假单胞菌抗原(St-Ag)的抗体出现情况进行了研究。通过中间凝胶的融合火箭免疫电泳发现,St-Ag以及所研究的任何其他抗原样本均能检测到针对铜绿假单胞菌产生沉淀抗体的体液免疫反应。6份血清中含有仅被所用一种抗原样本而非St-Ag所揭示的群特异性抗体。使用St-Ag以及源自相关患者感染的铜绿假单胞菌菌株制备的抗原,通过各种定量免疫电泳方法对这6份血清进行了进一步研究。在所有6份血清中,使用源自同源菌株而非St-Ag的抗原时,仅能检测到一种额外的沉淀素。这种额外的沉淀素大概对应于不包含在St-Ag中的群特异性O抗原。在患者血清中,这些群特异性抗体总是伴随着针对铜绿假单胞菌所有菌株共有的抗原的抗体。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验