• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Interrater reliability of craniosacral rate measurements and their relationship with subjects' and examiners' heart and respiratory rate measurements.

作者信息

Wirth-Pattullo V, Hayes K W

机构信息

Physical Therapy Ltd, Chicago, IL 60611.

出版信息

Phys Ther. 1994 Oct;74(10):908-16; discussion 917-20. doi: 10.1093/ptj/74.10.908.

DOI:10.1093/ptj/74.10.908
PMID:8090842
Abstract

BACKGROUND AND PURPOSE

The evaluation of craniosacral motion is an approach used by physical therapists and other health professionals to assess the causes of pain and dysfunction, but evidence for the existence of this motion is lacking and the reproducibility of the results of this palpatory technique has not been studied. This study examined the interexaminer reliability of craniosacral rate and the relationships among craniosacral rate and subjects' and examiners' heart and respiratory rates.

SUBJECTS

Participants were 12 children and adults with histories of physical trauma, surgery, or learning disabilities. Three physical therapists with expertise in craniosacral therapy were the examiners.

METHODS

One of three nurses recorded heart and respiratory rates of both subject and examiner. The examiner then palpated the subject to determine craniosacral rate and reported the findings to the nurse. Each subject was examined by each of the three examiners.

RESULTS

Reliability was estimated using a repeated-measures analysis of variance and the intraclass correlation coefficient (2,1). Significant differences among examiners and the scatter plot of rates showed lack of agreement among examiners. The ICC was -.02. The correlations between subject craniosacral rate and subject and examiner heart and respiratory rates were analyzed with Pearson correlation coefficients and were low and not statistically significant.

DISCUSSION AND CONCLUSIONS

Measurements of craniosacral motion did not appear to be related to measurements of heart and respiratory rates, and therapists were not able to measure it reliably. Measurement error may be sufficiently large to render many clinical decisions potentially erroneous. Further studies are needed to verify whether craniosacral motion exists, examine the interpretations of craniosacral assessment, determine the reliability of all aspects of the assessment, and examine whether craniosacral therapy is an effective treatment. [Wirth-Pattullo V. Hayes KW. Interrater reliability of craniosacral rate measurements and their relationship with subjects' and examiners' heart and respiratory rate measurements.

摘要

相似文献

1
Interrater reliability of craniosacral rate measurements and their relationship with subjects' and examiners' heart and respiratory rate measurements.
Phys Ther. 1994 Oct;74(10):908-16; discussion 917-20. doi: 10.1093/ptj/74.10.908.
2
Craniosacral rhythm: reliability and relationships with cardiac and respiratory rates.颅骶节律:可靠性及其与心率和呼吸频率的关系。
J Orthop Sports Phys Ther. 1998 Mar;27(3):213-8. doi: 10.2519/jospt.1998.27.3.213.
3
Simultaneous palpation of the craniosacral rate at the head and feet: intrarater and interrater reliability and rate comparisons.同时对头和足部进行颅骶节律触诊:评估者内及评估者间的可靠性及节律比较
Phys Ther. 1998 Nov;78(11):1175-85. doi: 10.1093/ptj/78.11.1175.
4
Intraexaminer and interexaminer reliability for palpation of the cranial rhythmic impulse at the head and sacrum.检查者自身及不同检查者之间对头和骶骨处颅骶节律性冲动触诊的可靠性。
J Manipulative Physiol Ther. 2001 Mar-Apr;24(3):183-90.
5
Inter- and intraexaminer reliability in palpation of the "primary respiratory mechanism" within the "cranial concept".
Man Ther. 2004 Feb;9(1):22-9. doi: 10.1016/s1356-689x(03)00099-7.
6
Intraobserver and interobserver reliability of asymptomatic subjects' thoracolumbar range of motion using the OSI CA 6000 Spine Motion Analyzer.使用OSI CA 6000脊柱运动分析仪对无症状受试者胸腰椎活动范围进行观察者内和观察者间可靠性研究。
J Orthop Sports Phys Ther. 1994 Oct;20(4):207-12. doi: 10.2519/jospt.1994.20.4.207.
7
Influence of examiner experience and gender on interrater reliability of KT-1000 arthrometer measurements.
Phys Ther. 1995 Oct;75(10):898-906. doi: 10.1093/ptj/75.10.898.
8
Changes in elongation of falx cerebri during craniosacral therapy techniques applied on the skull of an embalmed cadaver.在对一具防腐尸体的颅骨应用颅骶疗法技术过程中大脑镰伸长的变化。
Cranio. 1992 Jan;10(1):9-12. doi: 10.1080/08869634.1992.11677885.
9
Variance in the measurement of sagittal lumbar spine range of motion among examiners, subjects, and instruments.检查者、受试者和仪器之间腰椎矢状面活动度测量的差异。
Spine (Phila Pa 1976). 1995 Jul 1;20(13):1489-93. doi: 10.1097/00007632-199507000-00008.
10
A systematic review of craniosacral therapy: biological plausibility, assessment reliability and clinical effectiveness.颅骶疗法的系统评价:生物学合理性、评估可靠性和临床有效性。
Complement Ther Med. 1999 Dec;7(4):201-7. doi: 10.1016/s0965-2299(99)80002-8.

引用本文的文献

1
Applicability of using dynamic MRI to evaluate alleged cranial rhythmic impulse (CRI).应用动态 MRI 评估疑似颅节律冲动(CRI)。
BMC Musculoskelet Disord. 2024 Nov 21;25(1):941. doi: 10.1186/s12891-024-08064-y.
2
Reliability of Diagnosis and Clinical Efficacy of Cranial Osteopathy: A Systematic Review.颅骨整骨疗法的诊断可靠性与临床疗效:一项系统评价。
PLoS One. 2016 Dec 9;11(12):e0167823. doi: 10.1371/journal.pone.0167823. eCollection 2016.