• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Experience with the illuminated endotracheal tube in the prevention of unsafe intubations in the premature and full-term newborn.

作者信息

Heller R M, Heller T W

机构信息

Department of Radiology and Radiologic Sciences, Vanderbilt University Medical Center, Nashville, TN 37232.

出版信息

Pediatrics. 1994 Mar;93(3):389-91.

PMID:8115197
Abstract

OBJECTIVE

To determine whether an endotracheal tube modified by incorporation of a fiberoptic strand in the wall and connected to a light source could be safely and reliably positioned in premature and full-term newborns using transdermal siting of a bright spot on the skin at the suprasternal notch of the chest wall.

METHODS

All newborns in the Vanderbilt Neonatal Intensive Care Unit who were candidates for intubation by established clinical criteria, who were not already intubated, were candidates for the study. We defined optimal placement of the endotracheal tube to be one with the tip of the tube below the first thoracic vertebral body and no less than 0.5 cm above the carina or at T-4 (if the carina could not be seen on the radiograph). A light source was connected to the fiberoptic strand and the endotracheal tube positioned so that a circle of light was visible on the skin of the chest wall at the suprasternal notch.

RESULTS

In all 22 placements, the tube tip was below the larynx and above the carina. In 20 of the placements, the position was optimal between T-1 and T-4, whereas in the other 2 the tube tip was high between the larynx and the thoracic inlet. This system required that an endotracheal tube 0.5 mm smaller than usually used be utilized because of the slight increase in outer diameter due to the fiberoptic strand. Conventional suction catheters were used in this study.

CONCLUSIONS

This study has shown that the illuminated endotracheal tube is a reliable device for accurate positioning in premature and full-term newborns using transdermal siting of a bright spot on the skin at the suprasternal notch.

摘要

相似文献

1
Experience with the illuminated endotracheal tube in the prevention of unsafe intubations in the premature and full-term newborn.
Pediatrics. 1994 Mar;93(3):389-91.
2
Early experience with illuminated endotracheal tubes in premature and term infants.早产和足月婴儿使用发光气管内导管的早期经验。
Pediatrics. 1985 Apr;75(4):664-6.
3
Correct placement of endotracheal tube by single strand fiberoptic light in prematures. Initial clinical experience.单股纤维光学喉镜引导下气管内导管在早产儿中的正确放置。初步临床经验。
Padiatr Padol. 1991;26(5):227-8.
4
Endotracheal tube placement in infants determined by suprasternal palpation: a new technique.通过胸骨上触诊确定婴儿气管内插管位置:一种新技术。
Pediatrics. 1975 Aug;56(2):224-9.
5
[Finding appropriate endotracheal tube position by Trachlight in children].[使用Trachlight确定儿童气管内导管位置]
Masui. 2001 Feb;50(2):175-8.
6
[Finding appropriate tube position by the cuff palpation method in children].[通过袖带触诊法确定儿童气管导管位置]
Masui. 1995 Jun;44(6):845-8.
7
A randomized trial of suprasternal palpation to determine endotracheal tube position in neonates.一项关于胸骨上触诊以确定新生儿气管插管位置的随机试验。
Resuscitation. 2004 Mar;60(3):297-302. doi: 10.1016/j.resuscitation.2003.11.010.
8
Depth of endotracheal tubes in Thai adult patients.泰国成年患者气管内导管的深度
J Med Assoc Thai. 2005 Jun;88(6):775-81.
9
Women are at greater risk than men for malpositioning of the endotracheal tube after emergent intubation.在紧急插管后,女性发生气管内导管位置不当的风险高于男性。
Crit Care Med. 1994 Jul;22(7):1127-31. doi: 10.1097/00003246-199407000-00013.
10
Randomised trial of estimating oral endotracheal tube insertion depth in newborns using suprasternal palpation of the tip or weight.使用胸骨上切迹触诊尖端或重量估计新生儿经口气管插管插入深度的随机试验。
Arch Dis Child Fetal Neonatal Ed. 2020 Mar;105(2):196-200. doi: 10.1136/archdischild-2019-317328. Epub 2019 Jun 27.

引用本文的文献

1
Strategies to Improve Neonatal Intubation Safety by Preventing Endobronchial Placement of the Tracheal Tube-Literature Review and Experience at a Tertiary Center.通过预防气管导管进入支气管来提高新生儿插管安全性的策略——文献综述及某三级中心的经验
Children (Basel). 2023 Feb 11;10(2):361. doi: 10.3390/children10020361.