在全血流式细胞术检测中,放射造影剂对粒细胞吞噬大肠杆菌的影响。

Effect of radiographic contrast media on granulocyte phagocytosis of Escherichia coli in a whole blood flow cytometric assay.

作者信息

Lillevang S T, Albertsen M, Rasmussen F, Georgsen J, Egund N

机构信息

Department of Clinical Immunology, Odense University Hospital, Denmark.

出版信息

Invest Radiol. 1994 Jan;29(1):68-71. doi: 10.1097/00004424-199401000-00013.

Abstract

RATIONALE AND OBJECTIVES

Earlier studies have demonstrated an adverse effect of radiographic contrast media (CM) on granulocyte phagocytosis. Most studies in the past have depended on granulocyte separative procedures that may themselves affect granulocyte functions. This study was performed to evaluate the effect of CM on phagocytosis using a flow cytometric assay allowing more physiological assay conditions.

METHODS

Twenty consecutive patients were blindly randomized to receive the nonionic ratio 3.0 CM iohexol or the ionic ratio 3.0 CM ioxaglate for intravenous urography. Granulocyte phagocytic potential was measured before and at 1, 5, and 20 minutes after CM administration with a flow cytometric whole blood method evaluating the ingestion of complement- and immunoglobulin G (IgG)-opsonized fluorescent Escherichia Coli bacteria.

RESULTS

The ability of granulocytes to phagocytize opsonized E. Coli was adversely affected by both CM used. Compared with baseline values, significantly decreased phagocytic activity was observed for iohexol at 1, 5, and 20 minutes and for ioxaglate at 1 and 5 minutes. The largest decrease with ioxaglate was from 85.3 +/- 10.5 to 69.3 +/- 16.3 (5 minutes), and the largest change with iohexol was from 87.1 +/- 8.5 to 74.5 +/- 15.9 (5 minutes).

CONCLUSION

These results confirm earlier reports that ionic and nonionic CM adversely affect the phagocytic ability of granulocytes after intravenous administration.

摘要

原理与目的

早期研究已证明放射造影剂(CM)对粒细胞吞噬作用有不良影响。过去的大多数研究依赖于粒细胞分离程序,而这些程序本身可能会影响粒细胞功能。本研究旨在使用流式细胞术测定法评估CM对吞噬作用的影响,该方法能提供更接近生理状态的检测条件。

方法

连续20例患者被随机分为两组,分别接受非离子型比率为3.0的碘海醇CM或离子型比率为3.0的碘克沙酸CM进行静脉肾盂造影。在给予CM前以及给药后1、5和20分钟,采用流式细胞术全血法测量粒细胞吞噬潜能,该方法用于评估补体和免疫球蛋白G(IgG)调理的荧光大肠杆菌的摄取情况。

结果

两种使用的CM均对粒细胞吞噬调理后的大肠杆菌的能力产生了不良影响。与基线值相比,碘海醇在1、5和20分钟时以及碘克沙酸在1和5分钟时的吞噬活性均显著降低。碘克沙酸最大降幅为从85.3±10.5降至69.3±16.3(5分钟),碘海醇最大变化为从87.1±8.5降至74.5±15.9(5分钟)。

结论

这些结果证实了早期报告,即离子型和非离子型CM静脉给药后会对粒细胞的吞噬能力产生不良影响。