• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Suitability of the open loop lens Phacoflex XI-30 for capsular sick implantation by self-sealing sclerocorneal tunnel incisions].

作者信息

Menapace R, Papapanos P

机构信息

I. Universitäts-Augenklinik Wien.

出版信息

Klin Monbl Augenheilkd. 1994 Feb;204(2):111-20. doi: 10.1055/s-2008-1035507.

DOI:10.1055/s-2008-1035507
PMID:8170093
Abstract

SCOPE OF THE STUDY

We studied a new intraocular lens implant with a high-refractive silicone optic and prolene C-loops. Suitability for folding and implantation with the recommended instruments as well as its performance as a capsular bag implant were evaluated. The impact of the self-sealing wound construction used on postoperative corneal stability was also studied.

PATIENTS AND METHODS

We included 35 consecutively operated eyes. Capsulorhexis and phacoemulsification were performed. A well-centered and round 4-5 mm anterior capsular opening was aimed at. Using the Fine Universal or the Livernois-McDonald folder the optic was folded lengthwise and the leading loop tucked within the crease. The lens was implanted through a self-sealing sclerocorneal tunnel which measured 3.0 mm in length and 3.2 mm in width.

RESULTS

With the instrumentation described, a 3.2 mm incision was adequate. - The lens centered well. In one case each decentration resulted from an optic-edge-by-rhexis-rim capture with an inappropriately shaped rhexis and from excessive capsular bag shrinkage with a too small rhexis. As a rule, the posterior capsule was distended and, with five exceptions, firmly attached to the optic. Fibrosis had resulted in only two cases where the rhexis had evaded the optic edge. Except for a single case where a filtering procedure had been simultaneously performed, optic-to-iris clearance was pronounced in all cases. Consequently, signs of iris chafing were never seen and iridocapsular synechiae had never formed in the latter. - Typically, fine granules scattered within the material and a bluish-violet tint were noted. However, neither intensive haze nor brownish discoloration as well as shell- or inner contour-phenomena were never present. - Vector analysis showed a negligible initial astigmatic shift against the wound that did not progress further on.

CONCLUSION

This new implant performs very satisfactory. It may be even further improved by eliminating the granular inclusions and increasing the haptic rigidity. In order to prevent fibrotic opacification of the posterior capsule full circular overlap of the optic periphery by the anterior capsular leaf should be aimed at. The advantage of the reduced incision width required for insertion makes it very appropriate for clear corneal incision surgery.

摘要

相似文献

1
[Suitability of the open loop lens Phacoflex XI-30 for capsular sick implantation by self-sealing sclerocorneal tunnel incisions].
Klin Monbl Augenheilkd. 1994 Feb;204(2):111-20. doi: 10.1055/s-2008-1035507.
2
Evaluation of 35 consecutive SI-30 PhacoFlex lenses with high-refractive silicone optic implanted in the capsulorhexis bag.对连续35枚植入撕囊袋内的高折射硅凝胶光学部SI-30 PhacoFlex人工晶状体进行评估。
J Cataract Refract Surg. 1995 May;21(3):339-47. doi: 10.1016/s0886-3350(13)80144-7.
3
[Long-term outcome after implantation of various intraocular lenses through a corneal tunnel].[通过角膜隧道植入不同人工晶状体后的长期结果]
Klin Monbl Augenheilkd. 1997 Aug;211(2):106-12. doi: 10.1055/s-2008-1035105.
4
Long-term efficacy of adding a sharp posterior optic edge to a three-piece silicone intraocular lens on capsule opacification: five-year results of a randomized study.在三件式硅酮人工晶状体上添加锐利的后光学边缘对后囊膜混浊的长期疗效:一项随机研究的五年结果
Am J Ophthalmol. 2005 Apr;139(4):696-703. doi: 10.1016/j.ajo.2004.12.050.
5
Influence of optic edge design, optic material, and haptic design on capsular bend configuration.
J Cataract Refract Surg. 2005 Oct;31(10):1888-94. doi: 10.1016/j.jcrs.2005.03.072.
6
Optic edge design as long-term factor for posterior capsular opacification rates.视边缘设计作为后囊膜混浊率的长期影响因素。
Ophthalmology. 2008 Aug;115(8):1308-14, 1314.e1-3. doi: 10.1016/j.ophtha.2008.01.002. Epub 2008 Mar 5.
7
Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contraction.人工晶状体光学边缘设计与材料对纤维化囊膜混浊及撕囊收缩的影响
J Cataract Refract Surg. 2004 Sep;30(9):1875-82. doi: 10.1016/j.jcrs.2004.01.042.
8
Evaluation of the first 100 consecutive PhacoFlex silicone lenses implanted in the bag through a self-sealing tunnel incision using the Prodigy inserter.使用Prodigy插入器通过自密封隧道切口对连续植入囊袋内的首批100枚PhacoFlex硅胶人工晶状体进行评估。
J Cataract Refract Surg. 1994 May;20(3):299-309. doi: 10.1016/s0886-3350(13)80582-2.
9
Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge optics: randomized clinical trial.光学材料对锐边光学人工晶状体后囊膜混浊的影响:随机临床试验
Ophthalmology. 2005 Jan;112(1):67-72. doi: 10.1016/j.ophtha.2004.07.032.
10
[Cataract surgery with implantation of toric silicone lenses for severe astigmatism after keratoplasty].[角膜移植术后严重散光的散光型硅水凝胶人工晶状体植入白内障手术]
Klin Monbl Augenheilkd. 2004 Jun;221(6):489-94. doi: 10.1055/s-2004-813167.