Suppr超能文献

脑积水:零颅内压脑室分流术(ZIPS)控制重力性分流流量。56例患者的临床研究。

Hydrocephalus: the zero ICP ventricle shunt (ZIPS) to control gravity shunt flow. A clinical study in 56 patients.

作者信息

Foltz E L, Blanks J, Meyer R

机构信息

Department of Neurological Surgery, University California, Orange 92613-4091.

出版信息

Childs Nerv Syst. 1994 Jan;10(1):43-8. doi: 10.1007/BF00313584.

Abstract

Significant morbidity from ventricle shunt overdrainage at 6-7 years after initial shunt placement for hydrocephalus is increasingly recognized as due to excessive gravity-flow of shunted CSF when upright. Shunts are designed primarily to control high ICP. Shunts should also mimic normal upright ICP. Normal upright ICP is -65 mm of water (vertex reference), indicating that a level of zero ICP exists at 65 mm below the brain vertex, with negative ICP above and positive ICP below that level. This normal zero ICP level must be maintained by CSF shunts to mimic normal upright ICP. This will prevent and correct CSF shunt overdrainage. The zero ICP shunt (ZIPS) by design controls this zero level with a zero pressure device (ZPD; siphon control device) installed at the normal vertical level of zero ICP (cm/mm) below the vertex (65 mm). The shunt thus prevents excessive gravity-induced CSF shunt flow. Successful use of ZIPS in 56 patients is reported (low ICP group: n = 42; high ICP group: n = 14). Follow-up is up to 4.5 years. Results show that: (1) adjustability of ZPD level can achieve the desired clinical results; (2) the level of ZPD installed correlates within 4 mm of upright ICP attained; (3) the optimal level of ZPD installation to produce normal upright ICP is 65 mm below the vertex; (4) CT ventricle size, both slit ventricles and large ventricles, may or may not normalize when normal upright ICP is attained in this group of complex, previously shunted patients.

摘要

脑积水初次分流术后6至7年出现的脑室分流过度引流导致的显著发病率,越来越被认为是由于直立时分流的脑脊液重力流过大所致。分流器主要设计用于控制高颅内压。分流器还应模拟正常的直立颅内压。正常直立颅内压为-65毫米水柱(以头顶为参考),这表明在脑顶点下方65毫米处存在颅内压为零的水平,在此水平之上颅内压为负,在此水平之下颅内压为正。脑脊液分流器必须维持这个正常的零颅内压水平,以模拟正常的直立颅内压。这将预防和纠正脑脊液分流过度引流。零颅内压分流器(ZIPS)通过设计,利用安装在头顶下方正常垂直零颅内压水平(厘米/毫米)(65毫米)处的零压力装置(ZPD;虹吸控制装置)来控制这个零水平。因此,该分流器可防止重力引起的脑脊液分流过度。报告了ZIPS在56例患者中的成功应用(低颅内压组:n = 42;高颅内压组:n = 14)。随访时间长达4.5年。结果显示:(1)ZPD水平的可调节性可实现预期的临床效果;(2)安装的ZPD水平与达到的直立颅内压在4毫米范围内相关;(3)产生正常直立颅内压的ZPD最佳安装水平是在头顶下方65毫米处;(4)在这组复杂的、先前已分流的患者中,当达到正常直立颅内压时,CT脑室大小,无论是裂隙脑室还是大脑室,可能会也可能不会恢复正常。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验