Suppr超能文献

平衡液与生理盐水对大隐静脉移植物舒张作用的比较。

Comparison of saphenous vein graft relaxation between Plasma-Lyte solution and normal saline solution.

作者信息

Sanchez A M, Wooldridge T A, Boerboom L E, Olinger G N, Almassi G H, Rusch N J

机构信息

Department of Cardiothoracic Surgery, Medical College of Wisconsin, Milwaukee 53226.

出版信息

J Thorac Cardiovasc Surg. 1994 Jun;107(6):1445-53.

PMID:8196386
Abstract

Venospasm of saphenous vein grafts may damage endothelial cells and compromise early and late graft performance. Hence it is desirable to identify and use storage solutions that minimize vascular spasm during vein preparation. In view of this, we initiated isometric tension-recording studies in isolated canine and human saphenous vein to evaluate the acute, vasoactive effects of two storage solutions, Plasma-Lyte solution and normal saline solution. In initial experiments, canine saphenous veins were mounted in tissue baths containing physiologic salt solution and tonically constricted by 2 x 10(-6) mol/L norepinephrine. The physiologic salt solution in the bath was then replaced by Plasma-Lyte solution or normal saline solution containing the same norepinephrine concentration, and changes in contraction amplitude were recorded for 90 minutes. Storage in Plasma-Lyte solution at 37 degrees C completely relaxed norepinephrine-activated canine saphenous vein within 20 minutes, whereas veins remained partially constricted in normal saline solution. Both Plasma-Lyte solution and normal saline solution relaxed canine saphenous vein less at room temperature (25 degrees C) than at 37 degrees C, implying that warming of storage solutions in the operating room may promote graft dilation. To identify the mechanism by which Plasma-Lyte solution induced relaxation, we replaced its putative vasodilator components of gluconate and acetate with NaCl, but this alteration did not reduce relaxation induced by Plasma-Lyte solution. However, adding 1.6 mmol/L CaCl2 to Plasma-Lyte solution completely reversed the venodilation, suggesting that the low Ca2+ content of Plasma-Lyte solution confers its relaxant action. Finally, we tested the vasoactive effect of Plasma-Lyte solution on human saphenous vein obtained by discard from coronary bypass operations. Plasma-Lyte solution at 37 degrees C effectively dilated norepinephrine-activated human saphenous vein, inducing complete relaxation within 20 minutes. On this basis, we recommend the use of Plasma-Lyte solution as a venodilating storage solution during coronary bypass operations to optimize vein graft relaxation before implantation.

摘要

大隐静脉移植物的静脉痉挛可能会损伤内皮细胞,并影响移植物的早期和晚期性能。因此,需要识别并使用在静脉制备过程中能使血管痉挛最小化的保存溶液。鉴于此,我们开展了等长张力记录研究,以评估两种保存溶液(平衡液和生理盐水)对离体犬和人隐静脉的急性血管活性作用。在初始实验中,将犬隐静脉安装在含有生理盐溶液的组织浴槽中,并用2×10⁻⁶mol/L去甲肾上腺素进行张力性收缩。然后将浴槽中的生理盐溶液替换为含有相同去甲肾上腺素浓度的平衡液或生理盐水,并记录90分钟内收缩幅度的变化。在37℃下保存在平衡液中的静脉在20分钟内完全松弛了去甲肾上腺素激活的犬隐静脉,而在生理盐水中的静脉仍部分收缩。平衡液和生理盐水在室温(25℃)下对犬隐静脉的松弛作用均小于在37℃时,这意味着在手术室中加热保存溶液可能会促进移植物扩张。为了确定平衡液诱导松弛的机制,我们用氯化钠替代了其假定的血管扩张剂成分葡萄糖酸盐和醋酸盐,但这种改变并没有降低平衡液诱导的松弛作用。然而,向平衡液中添加1.6mmol/L氯化钙完全逆转了静脉扩张,这表明平衡液中低钙含量赋予了其松弛作用。最后,我们测试了平衡液对冠状动脉搭桥手术中废弃的人隐静脉的血管活性作用。37℃的平衡液有效地扩张了去甲肾上腺素激活的人隐静脉,在20分钟内诱导完全松弛。在此基础上,我们建议在冠状动脉搭桥手术中使用平衡液作为静脉扩张保存溶液,以在植入前优化静脉移植物的松弛。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验