• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Albuterol delivery by metered-dose inhaler with a pediatric mechanical ventilatory circuit model.

作者信息

Garner S S, Wiest D B, Bradley J W

机构信息

Department of Clinical Pharmacy and Pediatrics, Medical University of South Carolina, Charleston 29425.

出版信息

Pharmacotherapy. 1994 Mar-Apr;14(2):210-4.

PMID:8197041
Abstract

STUDY OBJECTIVE

To determine albuterol delivery by metered-dose inhaler (MDI) in an in vitro pediatric mechanical ventilatory circuit model. The influence of a spacing device, endotracheal tube (ETT) diameter and length, and air humidity was also investigated.

DESIGN

An albuterol MDI canister was connected to an AeroVent spacer or Airlife MDI adapter and ETT 4.0, 5.0, or 6.0 mm at commercially available and equal lengths. The ETT tip was attached to an in-line filter holder with a 1-microns type A/E glass fiber filter. Ventilator settings were fractional concentration of inspired oxygen 50%, tidal volume 250 ml, inspiratory:expiratory (I:E) ratio 1:3, rate 25 breaths/minute, temperature 35 degrees C, and a decelerating flow pattern. Ten albuterol canisters were activated two times each (total 2000 micrograms) into dry (4.0-, 5.0-, and 6.0-mm ETT) and humidified air (4.0- and 6.0-mm ETT) and repeated in triplicate. Percentage MDI output was determined by weighing the filter before and after drug administration (balance sensitivity 10 micrograms). Significant differences (p < or = 0.05) among the groups with and without a spacer and in dry and humidified air were determined by ANOVA with Scheffe's multiple comparison test. Multiple regression was used to determine significant associations between ETT diameter and length and delivery.

MAIN RESULTS

With the AeroVent spacer in humidified air, delivery with the 4.0- and 6.0-mm ETT was approximately 2.3% and 5%, respectively. The spacer and dry air significantly improved delivery.

CONCLUSIONS

In humidified air, the dose of albuterol by MDI with an AeroVent spacer should be doubled for children intubated with 6.0-mm ETT, and four puffs administered for every one puff desired for 4.0-mm ETT. The results of this investigation should prove useful in initial clinical trials of albuterol MDI in ventilator-dependent infants and children.

摘要

相似文献

1
Albuterol delivery by metered-dose inhaler with a pediatric mechanical ventilatory circuit model.
Pharmacotherapy. 1994 Mar-Apr;14(2):210-4.
2
Effect of heliox on albuterol delivery by metered-dose inhaler in pediatric in vitro models of mechanical ventilation.氦氧混合气对机械通气小儿体外模型中定量吸入器沙丁胺醇给药的影响。
Pharmacotherapy. 2006 Oct;26(10):1396-402. doi: 10.1592/phco.26.10.1396.
3
Albuterol delivery from a metered-dose inhaler with spacer is reduced following short-duration manual ventilation in a neonatal ventilator-lung model.在新生儿呼吸机-肺模型中,短时间手动通气后,使用带储雾罐的定量吸入器输送的沙丁胺醇量会减少。
Respir Care. 2004 Sep;49(9):1029-34.
4
A survey of albuterol administration practices in intubated patients in the neonatal intensive care unit.新生儿重症监护病房中插管患者沙丁胺醇给药实践的调查。
Respir Care. 2002 Jan;47(1):31-8.
5
A novel, versatile valved holding chamber for delivering inhaled medications to neonates and small children: laboratory simulation of delivery options.一种新型、多功能的带阀持气室,用于向新生儿和幼儿输送吸入性药物:输送方式的实验室模拟。
Respir Care. 2010 Apr;55(4):419-26.
6
Albuterol delivery by metered-dose inhaler in a mechanically ventilated pediatric lung model.
Crit Care Med. 1996 May;24(5):870-4. doi: 10.1097/00003246-199605000-00023.
7
Influence of moisture accumulation in inline spacer on delivery of aerosol using metered-dose inhaler during mechanical ventilation.机械通气期间,在线间隔器中水分积聚对使用定量吸入器输送气雾剂的影响。
Respir Care. 2009 Oct;54(10):1336-41.
8
Evaluation of aerosol generator devices at 3 locations in humidified and non-humidified circuits during adult mechanical ventilation.评价成人机械通气时在加湿和非加湿回路的 3 个位置的雾化器装置。
Respir Care. 2010 Jul;55(7):837-44.
9
Albuterol aerosol delivered via metered-dose inhaler to intubated pediatric models of 3 ages, with 4 spacer designs.通过定量吸入器将沙丁胺醇气雾剂输送给3个年龄段的插管儿科模型,并采用4种不同的储雾罐设计。
Respir Care. 2003 Oct;48(10):948-55.
10
Albuterol delivery during noninvasive ventilation.无创通气期间的沙丁胺醇给药
Respir Care. 2005 Dec;50(12):1649-53.

引用本文的文献

1
Two administration methods for inhaled salbutamol in intubated patients.气管插管患者吸入沙丁胺醇的两种给药方法。
Arch Dis Child. 2002 Jul;87(1):49-53. doi: 10.1136/adc.87.1.49.
2
Nebuliser therapy in the intensive care unit.重症监护病房中的雾化吸入治疗。
Thorax. 1997 Apr;52 Suppl 2(Suppl 2):S56-9. doi: 10.1136/thx.52.2008.s56.