Suppr超能文献

Swan-Ganz catheter-related pulmonary valve infective endocarditis: a case report.

作者信息

Bernardin G, Milhaud D, Roger P M, Pouliquen G, Corcelle P, Mattei M

机构信息

Service de Réanimation Médicale, Hôpital de l'Archet, Nice, France.

出版信息

Intensive Care Med. 1994;20(2):142-4. doi: 10.1007/BF01707670.

Abstract

We report the case of a 29-year-old man with decompensated alcoholic cardiomyopathy who developed a Staphylococcal pulmonic valve infective endocarditis during hemodynamic monitoring, as a consequence of catheter-related bacteremia. As experimentally demonstrated, the damaging role of the pulmonary artery catheter on the endocardial surface plays a major role in the pathogenesis of related right-sided infective endocarditis. Occurrence of bacteremia in a catheterized patient should be considered as a high risk situation, and righ-heart infective endocarditis must be suspected whenever patient presents fever or bacteremia without obvious site of infection. Doppler echocardiography is the reference diagnosis procedure.