Suppr超能文献

工业听力测试室中的环境噪声水平。

Ambient noise levels in industrial audiometric test rooms.

作者信息

Frank T, Williams D L

机构信息

Department of Communication Disorders, Penn State University, University Park 16802.

出版信息

Am Ind Hyg Assoc J. 1994 May;55(5):433-7. doi: 10.1080/15428119491018871.

Abstract

In 1983 the Occupational Safety and Health Administration (OSHA) specified maximum permissible ambient noise levels (MPANLs) that would allow valid hearing threshold measurements in an audiometric test room. However, ambient noise sound pressure levels (SPLs) in rooms used for industrial hearing tests are unknown. The present study reports octave band (125 to 8000 Hz) ambient noise SPLs measured in 490 single-walled prefabricated audiometric test rooms located in industrial settings that were obtained from eight sources. The ambient noise SPLs were highest in the lower frequencies and decreased as frequency increased. All 490 rooms met the OSHA MPANLs. Fortunately, the ambient noise SPLs were considerably lower than the OSHA MPANLs, since previous research has demonstrated that hearing thresholds cannot be obtained down to 0-dB HL in a test room having ambient noise levels equal to the OSHA MPANLs. In fact, 33%, or 162 of the 490 test rooms, met the more stringent MPANLs recently specified by the American National Standards Institute (ANSI) for industrial hearing testing. Given that the OSHA MPANLs are too high and that the test room ambient noise SPLs were considerably less than the OSHA MPANLs, that authors recommend that the OSHA MPANLs be revised to the more stringent ANSI 1991 MPANLs so that hearing thresholds for baseline and annual audiograms can be measured down to 0-dB HL.

摘要

1983年,美国职业安全与健康管理局(OSHA)规定了最大允许环境噪声水平(MPANLs),以便在听力测试室进行有效的听力阈值测量。然而,用于工业听力测试的房间内的环境噪声声压级(SPLs)尚不清楚。本研究报告了在位于工业环境中的490个单壁预制听力测试室中测量的倍频程带(125至8000 Hz)环境噪声声压级,这些测试室来自八个来源。环境噪声声压级在较低频率下最高,并随着频率增加而降低。所有490个房间均符合OSHA的MPANLs。幸运的是,环境噪声声压级远低于OSHA的MPANLs,因为先前的研究表明,在环境噪声水平等于OSHA的MPANLs的测试室中,无法获得低至0 dB HL的听力阈值。事实上,490个测试室中有33%(即162个)符合美国国家标准学会(ANSI)最近为工业听力测试规定的更严格的MPANLs。鉴于OSHA的MPANLs过高,且测试室环境噪声声压级远低于OSHA的MPANLs,作者建议将OSHA的MPANLs修订为更严格的ANSI 1991 MPANLs,以便能够测量基线和年度听力图的听力阈值低至0 dB HL。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验