顺应性对小口径聚氨酯移植物通畅性的影响。

Compliance effects on small diameter polyurethane graft patency.

作者信息

Uchida N, Kambic H, Emoto H, Chen J F, Hsu S, Murabayshi S, Harasaki H, Nosé Y

机构信息

Cleveland Clinic Foundation, Department of Biomedical Engineering, Ohio 44195.

出版信息

J Biomed Mater Res. 1993 Oct;27(10):1269-79. doi: 10.1002/jbm.820271007.

Abstract

Microporous compliance matched and noncompliant grafts were compared in a dog carotid artery interposition model. We fabricated 4 mm diameter sponge type polyurethane (Biomer) tubes 5 cm in length with a 0.5 mm wall thickness. The luminal surface was covered with a 50 microns coating of cross-linked gelatin. Compliance was measured in vitro and in vivo by volume and vessel diameter changes. Over a mean arterial pressure range of 55-155 mm Hg, the diameter changes of grafts and stump arteries were measured in situ using an ultrasonic Hokanson device. Compliance matched grafts were found to have the same in vitro compliance values as the natural canine carotid at a mean arterial pressure of 100 mm Hg. Compliance matched and noncompliant grafts had values of 10.3 +/- 1.3 and 0.9 +/- 0.1 x 10(-2) mm Hg, respectively. End to end arterial anastomoses were constructed between the graft and the host arteries. The use of synthetic grafts with matched compliance to the adjacent natural vessels has been advocated as the ideal solution to circumvent the problems of graft failure. These studies indicate that compliance values for compliance matched grafts decreased immediately after implantation (from 10.3 to 6.5 x 10(-2) %/mm Hg) and within 6 weeks decreased to 3.6 x 10(-2) %/mm Hg. The compliance values for noncompliant grafts remained constant throughout the test period. At autopsy all grafts showed a tightly adhered tissue capsule. The thickness of the anastomotic hyperplasia at the distal sites of compliance matched grafts was significantly different (P < .05) than that of the adjacent artery. The patency for compliant and noncompliant grafts was 64% and 50%, respectively. Evidence for polyurethane graft degradation was obtained by Fourier transform infrared spectroscopy and gel permeation chromatography analysis of patent explants. Compliance mismatch alone does not contribute to graft failure, however, material degradation, suture technique and/or capsule formation can play a contributory role although these were not tested directly.

摘要

在犬颈动脉置换模型中比较了微孔顺应性匹配和不匹配的移植物。我们制作了直径4毫米、长度5厘米、壁厚0.5毫米的海绵型聚氨酯(Biomer)管。管腔内表面覆盖有50微米厚的交联明胶涂层。通过体积和血管直径变化在体外和体内测量顺应性。在平均动脉压范围为55 - 155毫米汞柱时,使用超声Hokanson装置原位测量移植物和残端动脉的直径变化。发现顺应性匹配的移植物在平均动脉压为100毫米汞柱时具有与天然犬颈动脉相同的体外顺应性值。顺应性匹配和不匹配的移植物的值分别为10.3±1.3和0.9±0.1×10⁻²毫米汞柱。在移植物和宿主动脉之间构建端端动脉吻合。提倡使用与相邻天然血管顺应性匹配的合成移植物作为规避移植物失败问题的理想解决方案。这些研究表明,顺应性匹配移植物的顺应性值在植入后立即下降(从10.3降至6.5×10⁻²%/毫米汞柱),并在6周内降至3.6×10⁻²%/毫米汞柱。不匹配移植物的顺应性值在整个测试期间保持恒定。尸检时所有移植物均显示有紧密附着的组织包膜。顺应性匹配移植物远端部位吻合口增生的厚度与相邻动脉有显著差异(P < 0.05)。顺应性和不匹配移植物的通畅率分别为64%和50%。通过对通畅的外植体进行傅里叶变换红外光谱和凝胶渗透色谱分析获得了聚氨酯移植物降解的证据。然而,单独的顺应性不匹配并不导致移植物失败,尽管未直接测试,但材料降解、缝合技术和/或包膜形成可能起作用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验