Human basic tear fluid osmolality. I. Importance of sample collection strategy.

作者信息

White K M, Benjamin W J, Hill R M

机构信息

School of Optometry, University of Alabama at Birmingham.

出版信息

Acta Ophthalmol (Copenh). 1993 Aug;71(4):524-9. doi: 10.1111/j.1755-3768.1993.tb04630.x.

Abstract

Osmolalities of 200 human tear prism fluid samples collected from two subjects were determined from their melting-point temperatures with the Clifton Nanoliter Osmometer by calibration with 200 standard solution samples (290 mOsm/kg). Comparisons were made between tear fluid osmolalities obtained using a single-sample simultaneous-recalibration method: 1) for tear samples collected using finely-drawn microcapillaries without biomicroscopy, vs secondly with biomicroscopic observation by illumination of only the sampling area on the inferior tear prism, the two collections separated by an interval of 10 min; and 2) for samples collected without biomicroscopy before, vs after a 10-min interval. Tear fluid collection using a biomicroscope resulted in values that were significantly lower than those collected without (overall mean = 299.5 and 306.6 mOsm/kg, respectively; p < 0.0001). The difference (7.1 mOsm/kg) may have resulted from mechanical, photic, and/or psychogenic reflex stimulation due to biomicroscopy, as the 10-min interval had no osmotic effect on samples collected without biomicroscopy. Based on these results from two subjects, we suggest that relatively rapid, repetitive collections of human tear prism fluid can be made without significantly disturbing the osmotic outcome. However, physiological representation of basic human tear fluid is more accurate by avoidance of reflex-inducing collection methods that were formerly considered unobtrusive. Basic human tear prism fluid is more hypertonic, by at least 7 mOsm/kg, than generally realized.

摘要

使用Clifton纳升渗透压计,通过对200个标准溶液样本(290 mOsm/kg)进行校准,从两名受试者采集的200份人泪膜液样本的熔点温度来测定其渗透压。使用单样本同步重新校准方法对泪液渗透压进行了比较:1)使用精细拉制的微量毛细管在无生物显微镜观察的情况下采集泪液样本,与其次在仅对下泪膜采样区域进行照明的生物显微镜观察下采集泪液样本进行比较,两次采集间隔10分钟;2)比较之前在无生物显微镜观察下采集的样本与间隔10分钟后采集的样本。使用生物显微镜采集的泪液样本值显著低于无生物显微镜观察采集的值(总体平均值分别为299.5和306.6 mOsm/kg;p < 0.0001)。差异(7.1 mOsm/kg)可能是由于生物显微镜检查引起的机械、光和/或心理反射刺激所致,因为10分钟的间隔对无生物显微镜观察采集的样本没有渗透作用。基于两名受试者的这些结果,我们建议可以相对快速、重复地采集人泪膜液,而不会显著干扰渗透压结果。然而,通过避免以前认为不显眼的反射诱导采集方法,能更准确地呈现人基础泪液的生理状态。人基础泪膜液比一般认识的至少高渗7 mOsm/kg。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验