Suppr超能文献

Long-term follow-up of the experimental replacement of the esophagus with a collagen-silicone composite tube.

作者信息

Takimoto Y, Okumura N, Nakamura T, Natsume T, Shimizu Y

机构信息

Research Center for Biomedical Engineering, Kyoto University, Japan.

出版信息

ASAIO J. 1993 Jul-Sep;39(3):M736-9.

PMID:8268635
Abstract

This study investigated ways of preventing late stenosis after replacing the esophagus with a prosthetic device and increasing survival time in an animal model. In a previous study, the authors induced neoesophageal formation and re-epithelialization at an early stage, although stenosis in the chronic stage remained a problem, and long-term survival was prevented. The authors developed an artificial esophagus made from a collagen-silicone composite tube. The silicone tube (25 mm in diameter, 50 mm long, and 1 mm thick) was covered with collagen sponge (5 mm thick). The collagen sponge was intended to be replaced by host tissue, leading to neoesophageal regeneration. The authors thought stenosis was caused primarily by poor regeneration of submucosal tissue, rather than reepithelialization. Thus, they examined the grade of stenosis relative to the time the stent became dislodged. They concluded that the occurrence of stenosis after anastomosis depends upon the duration of stenting and that stenosis did not develop when the portion replaced by the artificial esophagus was stented for at least 4 weeks.