Heier H E, Kornstad L
Blodbank og immunologisk avdeling, Ullevål sykehus, Oslo.
Tidsskr Nor Laegeforen. 1993 Oct 20;113(25):3155-8.
A programme for external quality control in blood group serology has been run in Norway since 1983 by the National Institute of Public Health. Uncomplicated AB0 and Rh(D) grouping, including Du typing, has been performed satisfactorily. Rh(D) grouping of presensitized, Rh (D) negative cells is still a problem, but one which has been reduced significantly. Both indirect and direct antiglobulin reactions have given about 15% false negative results, mainly with weak antibodies and weakly sensitized cells. Poor training of technicians in reading weak agglutination reactions may be an important source of error. The importance of post-graduate training of blood bank staff is emphasized.
自1983年以来,挪威国家公共卫生研究所一直在开展血型血清学外部质量控制项目。简单的ABO和Rh(D)血型鉴定,包括Du分型,一直执行得令人满意。对已致敏的Rh(D)阴性细胞进行Rh(D)血型鉴定仍然是个问题,但这个问题已显著减少。间接和直接抗球蛋白反应均出现了约15%的假阴性结果,主要是针对弱抗体和弱致敏细胞。技术人员在读取弱凝集反应方面培训不足可能是一个重要的误差来源。强调了对血库工作人员进行研究生培训的重要性。