Suppr超能文献

Small animal imaging with pinhole single-photon emission computed tomography.

作者信息

Strand S E, Ivanovic M, Erlandsson K, Franceschi D, Button T, Sjögren K, Weber D A

机构信息

Radiation Physics Department, Lund University, Sweden.

出版信息

Cancer. 1994 Feb 1;73(3 Suppl):981-4. doi: 10.1002/1097-0142(19940201)73:3+<981::aid-cncr2820731334>3.0.co;2-n.

Abstract

BACKGROUND

High resolution spatial details of the distribution of activity in three dimensions is required to evaluate the localization and dosimetric properties of radiolabelled monoclonal antibodies in tumors and normal tissues. Planar imaging of small animals with a resolution of 5-10 mm is usually the imaging modality of choice. The authors investigated high resolution single-photon emission computed tomographic (SPECT) imaging, based on a rotating pinhole scintillation camera. Although the sensitivity of the pinhole collimator is low, several radionuclides offer suitable decay properties to perform pinhole SPECT, especially in conjunction with high activity levels used in radioimmunotherapy.

METHODS

Transverse, sagittal, and coronal sections were reconstructed using a three-dimensional cone-beam algorithm, which is a generalization of the two-dimensional fan-beam filtered backprojection algorithm. Before reconstruction, the pinhole projections were corrected for the decay of the radionuclide, geometric and intrinsic efficiency variations of the camera system, and center of rotation shift.

RESULTS

The spatial resolution at 50 mm from the pinhole collimator with 3.3 mm aperture was 3.4 mm, and the sensitivity 7.2 c/s microCi for technetium-99m. With the 2 mm collimator the resolution was 2.2 mm, and the sensitivity was 2.6 c/s/microCi. To show the spatial resolution in vivo, a rat was injected with 185 MBq of technetium-99m-methylene diphosphonate or with 5 mCi technetium-99m-hexamethylpropylene amine oxime. The bone structures were well delineated in the methylene diphosphonate image, and in the hexamethylpropylene amine oxime image, the brain was nicely shown. For comparison a magnetic resonance image for the same section was done.

CONCLUSIONS

High resolution SPECT imaging with the pinhole collimator provides mapping of the activity in three-dimensions, needed for more detailed biodistribution data and to perform more accurate dosimetry.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验