Tarpey A, Neithercut W D
Department of Chemical Pathology Wirral Hospital NHS Trust.
J Clin Pathol. 1993 May;46(5):459-61. doi: 10.1136/jcp.46.5.459.
To investigate the waste of laboratory reagents which resulted from the process of ordering biochemistry profiles.
The frequency of measurement of 15 analytes was recorded during the six months before the introduction of a system of discretionary requesting and analysis of samples (high capacity multichannel discrete analyser), and also during the same six month period one year and two years after its introduction.
The frequency of measurement of 10 of the 15 analytes decreased during the six month period one year after the change to discretionary testing. The remaining five analytes were measured up to 22% more frequently. There was an overall decrease in the measurement of biochemical tests by 31,359. This created an annual cost saving of 7124 pounds. In the second year five analytes still continued to be measured less frequently than originally but the remaining 10 analytes were measured more frequently. This resulted in an overall increase in the measurement of biochemical tests by 53,678 compared with the six month period before discretionary analysis. The pattern of requests was similar during both periods of discretionary requesting studied and as a result, a small annual cost saving of 1672 pounds was again made.
Discretionary requesting and analysis of tests may eliminate the measurement of clinically unnecessary test which had previously resulted from the processes of ordering tests. These cost savings may be rapidly eroded by an increase in the laboratory workload.
调查生化检验申请过程中导致的实验室试剂浪费情况。
在采用样本自行申请和分析系统(高容量多通道离散分析仪)之前的六个月以及引入该系统后的一年和两年的同一六个月期间,记录15种分析物的测量频率。
在改为自行检测后的一年中的六个月期间,15种分析物中有10种的测量频率下降。其余5种分析物的测量频率最多增加了22%。生化检验的测量总体减少了31359次。这每年节省了7124英镑的成本。在第二年,5种分析物的测量频率仍继续低于最初水平,但其余10种分析物的测量频率更高。与自行分析前的六个月期间相比,这导致生化检验的测量总体增加了53678次。在研究的两个自行申请期间,申请模式相似,因此再次实现了每年1672英镑的小幅成本节省。
自行申请和分析检验可能会消除此前因检验申请流程导致的临床不必要检验的测量。这些成本节省可能会因实验室工作量的增加而迅速被抵消。