We developed a system to automate a Flow Cytometry Clinical and Research Laboratory. Five major functions are accomplished: 1) patient demographic data entry, 2) specimen results data transfer, 3) procedure transcription and reporting, 4) data query, and 5) data backup and archiving. These are achieved by inter-linking two computers with dissimilar operating systems with a Fluorescence Activated Cell Analyzer (FACScan), several commercially available software systems, an IEEE-488 GPIB parallel cable interface using IEEE protocol and Hewlett Packard User Group software (HPPCLINK), and a customized in-house developed laboratory automation system for integrated database management. The system consists of data entry and editing, procedure results reporting, data query, and data archiving modules. The system design ensures data integrity, quality, and confidentiality.
我们开发了一个系统,用于实现流式细胞术临床和研究实验室的自动化。该系统完成了五项主要功能:1)患者人口统计学数据录入;2)标本结果数据传输;3)程序转录和报告;4)数据查询;5)数据备份和存档。这些功能通过以下方式实现:将两台运行不同操作系统的计算机与一台荧光激活细胞分析仪(FACScan)、多个商用软件系统、一个使用IEEE协议的IEEE-488 GPIB并行电缆接口以及惠普用户组软件(HPPCLINK)相互连接,并使用一个定制的内部开发的实验室自动化系统进行集成数据库管理。该系统由数据录入与编辑、程序结果报告、数据查询和数据存档模块组成。系统设计确保了数据的完整性、质量和保密性。