Implementation of the ETAR method for 3D inhomogeneity correction using FFT.

作者信息

Yu C X, Wong J W

机构信息

Washington University School of Medicine, St. Louis, Missouri.

出版信息

Med Phys. 1993 May-Jun;20(3):627-32. doi: 10.1118/1.597010.

Abstract

The equivalent tissue-air-ratio (ETAR) method employs three-dimensional (3D) CT pixel information to approximate scatter dose contribution for inhomogeneity correction. In general, the calculation provides better agreement with measurements than the one-dimensional (1D) methods typically used in commercial treatment planning systems. In its original implementation, the 3D formulation of the ETAR method is modified empirically as a 2D calculation in order to reduce computation time. The modification compromises the use of the method in several treatment geometries. An examination of the ETAR formulation shows that the calculation can be expressed as a convolution and thus can be performed in 3D using fast Fourier transform (FFT) techniques. The algorithm has been implemented as a 3D FFT convolution. Making use of the symmetric properties of the FFT, the new approach shows significant savings in computation time without excessive memory requirement. Despite its fundamental limitations when applied to regions of electronic disequilibrium, the ETAR method offers a practical solution to improving current dose calculation in 3D treatment planning, particularly when the more advanced scatter ray-tracing dose calculation algorithms remain impractical for clinical use. Recent work to extend the method to approximate electron transport is also encouraging.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验