Suppr超能文献

用于评估糖尿病患者血糖的龈沟血。

Gingival crevicular blood for assessment of blood glucose in diabetic patients.

作者信息

Parker R C, Rapley J W, Isley W, Spencer P, Killoy W J

机构信息

Department of Periodontics, University of Missouri-Kansas City, School of Dentistry.

出版信息

J Periodontol. 1993 Jul;64(7):666-72. doi: 10.1902/jop.1993.64.7.666.

Abstract

In this study 50 patients with diabetes mellitus had gingival crevicular blood from periodontal probing collected in small plastic pipettes. The pipettes transferred the crevicular blood to a non-wipe glucose self-monitoring instrument. At the same time, finger-stick capillary blood measurements were analyzed in the same glucose self-monitoring instrument, and venous blood was collected for measurement in a laboratory glucose analyzer. Each laboratory measurement was corrected from a serum glucose value to a whole blood glucose value by a function of the patient's hematocrit. This corrected glucose value allowed direct comparison of the laboratory measurement to the intraoral and finger-stick whole blood measurements. The patient blood glucose concentrations ranged from 59 mg/dl to 366 mg/dl. The gingival crevicular blood exhibited a correlation of r = 0.975 (P < .0001) to the corrected laboratory standard measurement, with a mean prediction error (bias) of -4.11 mg/dl and a root mean square error (precision) of 17.43 mg/dl. The finger-stick blood had a correlation of r = 0.983 (P < .0001) to the corrected laboratory standard, with a mean prediction error of 4.65 mg/dl and a root mean square error of 14.48 mg/dl. The American Diabetic Association recommends that the prediction error of blood glucose monitoring devices fall within 15% of the laboratory standard. Using this criterion 92% of the gingival crevicular measurements and 90% of the finger-puncture measurements fell within 15% of the laboratory value.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

在本研究中,50例糖尿病患者的龈沟血通过小型塑料移液器从牙周探诊处采集。移液器将龈沟血转移至一台免擦拭血糖自我监测仪。与此同时,在同一台血糖自我监测仪上分析手指末梢毛细血管血测量值,并采集静脉血在实验室血糖分析仪上进行测量。通过患者血细胞比容函数将每个实验室测量值从血清葡萄糖值校正为全血葡萄糖值。这种校正后的葡萄糖值使得能够将实验室测量值与口腔内和手指末梢全血测量值进行直接比较。患者血糖浓度范围为59mg/dl至366mg/dl。龈沟血与校正后的实验室标准测量值的相关性为r = 0.975(P <.0001),平均预测误差(偏差)为-4.11mg/dl,均方根误差(精密度)为17.43mg/dl。手指末梢血与校正后的实验室标准的相关性为r = 0.983(P <.0001),平均预测误差为4.65mg/dl,均方根误差为14.48mg/dl。美国糖尿病协会建议血糖监测设备的预测误差应在实验室标准的15%以内。按照这一标准,92%的龈沟测量值和90%的手指穿刺测量值落在实验室值的15%以内。(摘要截短为250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验