Suppr超能文献

健康年轻人群足部背部皮肤的激光多普勒静息通量、通量运动频率和幅度。

Laser Doppler resting fluxes, flux motion frequencies and amplitudes at the skin of the dorsum of the foot in healthy young humans.

作者信息

Van den Brande P, Derde M P, Von Kemp K, Vanhulle A

机构信息

Department of Surgery, Academic Hospital, Brussels, Belgium.

出版信息

Int Angiol. 1993 Mar;12(1):40-6.

PMID:8376910
Abstract

The complex microvascular geometry and the spatially heterogeneous perfusion of the skin seem to limit the application of Laser Doppler flowmetry (LDF) in resting conditions because of the large spatial variations that these microvascular measurements can show in even very adjacent areas of the dermal mantle. In this study cutaneous LDF was carried out at three spatially different areas of the dorsum of the foot in 22 young (mean age 25.5 years) and healthy human subjects: microvascular resting flux, flux frequency and flux amplitude as well as the distal tissue perfusion pressure as a macrovascular parameter and the skin temperature were measured. Intraindividually marked variations of the microvascular variables often existed between the three areas, but the variability was significantly different (p < 0.001): the resting flux yielded a variation coefficient (VC) of 36.2%, the amplitude of flux waves a VC of 20.2%, while the frequency of flux waves was a very precise individual parameter (VC 7.4%). Interindividually the variation of all three flux parameters was still significantly greater than intraindividually, but the mean value of all the subjects was the same in all three areas: mean resting flux was resp. 2.32, 2.23 and 2.44 arbitrary units (AU); mean frequency of flux waves 5.15, 4.96 and 4.90 cycles min-1; mean amplitude of flux waves 0.34, 0.36 and 0.36 AU. At last, no correlation existed between any of the microvascular flux variables on the one hand and the distal tissue perfusion pressure and skin temperature on the other hand.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

由于在真皮层的相邻区域微血管测量可能显示出较大的空间差异,皮肤复杂的微血管几何结构和空间异质性灌注似乎限制了激光多普勒血流仪(LDF)在静息状态下的应用。在本研究中,对22名年轻(平均年龄25.5岁)健康人类受试者足部背侧三个空间不同区域进行了皮肤LDF测量:测量了微血管静息通量、通量频率和通量幅度,以及作为大血管参数的远端组织灌注压和皮肤温度。三个区域之间微血管变量通常存在个体内显著差异(p<0.001):静息通量的变异系数(VC)为36.2%,通量波幅度的VC为20.2%,而通量波频率是一个非常精确的个体参数(VC为7.4%)。个体间所有三个通量参数的变异仍显著大于个体内变异,但所有受试者在三个区域的平均值相同:平均静息通量分别为2.32、2.23和2.44任意单位(AU);通量波平均频率为5.15、4.96和4.90次/分钟;通量波平均幅度为0.34、0.36和0.36 AU。最后,一方面任何微血管通量变量与另一方面的远端组织灌注压和皮肤温度之间均无相关性。(摘要截短于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验