Tonndorf J
Acta Otolaryngol. 1977 Jan-Feb;83(1-2):113-22. doi: 10.3109/00016487709128820.
Basilar membrane displacements in response to sound at threshold intensities are in the fractional Angstrom range. Visual measurements, as used by Bekesy in his pioneering studies, are by definition limited to values above 10 000 A. The present paper discusses a number of modern techniques capable of taking measurements at lower Anstrom levels: One-point methods (capacitive probe, Mossbauer effect, laser interferometry, and optical heterodyne spectroscopy) and pattern-assessing methods (time-averaged and real-time holography). Advantages and disadvantages of these methods are being discussed.
在阈值强度下,基底膜对声音的位移处于分数埃的范围内。贝凯西在其开创性研究中所使用的视觉测量方法,根据定义仅限于测量高于10000埃的值。本文讨论了一些能够在更低的埃级别进行测量的现代技术:单点测量方法(电容式探头、穆斯堡尔效应、激光干涉测量法和光学外差光谱法)以及图案评估方法(时间平均全息术和实时全息术)。文中还讨论了这些方法的优缺点。