Suppr超能文献

有对比剂诱发急性肾衰竭风险患者的肾功能:无创实时监测

Renal function in patients at risk of contrast material-induced acute renal failure: noninvasive, real-time monitoring.

作者信息

Rabito C A, Fang L S, Waltman A C

机构信息

Department of Radiology, Massachusetts General Hospital, Boston 02114.

出版信息

Radiology. 1993 Mar;186(3):851-4. doi: 10.1148/radiology.186.3.8430198.

Abstract

Real-time changes in renal function were studied in a group of 20 patients at risk of contrast-material-induced acute renal failure during different angiographic procedures. Renal function was evaluated with an ambulatory renal monitor (ARM) after a single injection of the glomerular filtration agent technetium-99m diethylenetriaminepentaacetic acid (DTPA). The ARM was used to continuously monitor the clearance of Tc-99m DTPA activity from the extracellular space in the arm of the patient during angiography. A one-compartment model was used to calculate on-line the rate constant for clearance of Tc-99m DTPA from the extracellular space. Changes in the rate constant were compared with changes in plasma creatinine level measured 1-4 days after angiography. The results showed that the ARM measured rapid changes in renal function during angiography with a resolution time of 5-10 minutes in patients with normal to moderately decreased renal function and 15-20 minutes in patients with severe renal dysfunction. The sensitivity of this technique was superior to that of plasma creatinine level analysis.

摘要

在一组20例有造影剂诱发急性肾衰竭风险的患者中,研究了不同血管造影操作期间肾功能的实时变化。在单次注射肾小球滤过剂锝-99m二乙三胺五乙酸(DTPA)后,使用动态肾脏监测仪(ARM)评估肾功能。在血管造影期间,ARM用于连续监测患者手臂中锝-99m DTPA活性从细胞外间隙的清除情况。使用单室模型在线计算锝-99m DTPA从细胞外间隙清除的速率常数。将速率常数的变化与血管造影后1至4天测得的血浆肌酐水平变化进行比较。结果表明,在肾功能正常至中度降低的患者中,ARM在血管造影期间测量肾功能的快速变化,分辨时间为5至10分钟,在严重肾功能不全的患者中为15至20分钟。该技术的敏感性优于血浆肌酐水平分析。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验