Busch H P, Lehmann K J, Georgi M
Institut für Klinische Radiologie, Klinikum Mannheim.
Aktuelle Radiol. 1993 Jan;3(1):6-13.
For chest imaging new analog and digital imaging techniques are now available. In this publication the imaging methods conventional film/screen, asymmetric film/screen("In-Sight"), slit(AMBER)-technique, spotfilm(100 mm)-technique, storage phosphor radiography and digital image intensifier radiography are compared. The clinical value is discussed by measured imaging capabilities and patient examinations. The highest image quality was demonstrated by the slit(AMBER)-technique. In comparison to conventional film/screen, storage phosphor radiography and asymmetric film/screen was graded higher only in the mediastinal field. Because of the low spatial resolution the image quality of digital image intensifier radiography was classified too poor for chest imaging.
对于胸部成像,现在有了新的模拟和数字成像技术。在本出版物中,对传统胶片/屏、不对称胶片/屏(“In-Sight”)、狭缝(AMBER)技术、点片(100毫米)技术、存储磷光体射线照相术和数字影像增强器射线照相术等成像方法进行了比较。通过测量成像能力和对患者的检查来讨论其临床价值。狭缝(AMBER)技术显示出最高的图像质量。与传统胶片/屏相比,存储磷光体射线照相术和不对称胶片/屏仅在纵隔区域的评分较高。由于空间分辨率低,数字影像增强器射线照相术的图像质量被判定对于胸部成像来说太差。