Abstract

From the Swedish Knee Arthroplasty project, started in 1975, types of relatively unmodified knee prostheses were chosen for analysis of time-dependent changes in the failure rate. One thousand nine hundred sixty-nine Marmor unicompartmental and 376 Total Condylar arthroplasties, all cemented, were followed until the end of 1989. The cumulative revision rates calculated with survival statistics showed a continuous improvement with time. The five-year revision rate was reduced from 11% to 5% for the Marmor prosthesis and from 10% to 2% for the Total Condylar prosthesis. This indicates that factors other than improved design are important. Such factors could include improved guide instruments, better surgical and cementing technique, influence of a learning curve, and patient selection.

摘要

从1975年启动的瑞典膝关节置换项目中,选择了类型相对未改良的膝关节假体,以分析失败率随时间的变化。1969例Marmor单髁关节置换术和376例全髁关节置换术,均为骨水泥固定,随访至1989年底。用生存统计计算的累积翻修率显示,随时间持续改善。Marmor假体的五年翻修率从11%降至5%,全髁假体从10%降至2%。这表明,除了设计改进之外,其他因素也很重要。这些因素可能包括改进的导向器械、更好的手术和骨水泥技术、学习曲线的影响以及患者选择。