Suppr超能文献

Centration of excimer laser photorefractive keratectomy relative to the pupil.

作者信息

Cavanaugh T B, Durrie D S, Riedel S M, Hunkeler J D, Lesher M P

出版信息

J Cataract Refract Surg. 1993;19 Suppl:144-8. doi: 10.1016/s0886-3350(13)80398-7.

Abstract

The centration of excimer laser photorefractive keratectomy (PRK) is critical to the procedure's success. We evaluated PRK centration in 49 patients using the EyeSys topography system. Ablation zone centration was measured from the corneal vertex and from the pupillary center using the pupil-finding software. Centration was measured more accurately from the pupillary center (0.40 mm) than from the corneal vertex (0.44 mm). Right eyes were decentered less than left eyes. There was an unpredictable correlation between amount of decentration and postoperative visual acuities. The ability to measure centration of keratorefractive procedures precisely from the pupil is an important advance in topography technology.