• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

床边心电图监测。

Bedside electrocardiogram monitoring.

作者信息

Drew B J

出版信息

AACN Clin Issues Crit Care Nurs. 1993 Feb;4(1):25-33.

PMID:8452741
Abstract

A recent national survey of critical care nurses reveals that the leads many nurses select to monitor their patients are diagnostically inferior to other available leads, and that lead placement often is inaccurate. This article reviews the best leads for electrocardiographic (ECG) monitoring, illustrates their accurate placement, and explains reasons for the dilemma in current practice. Questions relevant to practicing nurses are addressed, including 1) Is lead MCL1 as good as V1? 2) When is it appropriate to substitute lead MCL1 for V1? and 3) How important is it for electrodes to be placed exactly in specific anatomic locations? Finally, a case study is provided to illustrate how accurate monitoring can prevent misdiagnosis and resultant inappropriate therapy.

摘要

最近一项针对重症监护护士的全国性调查显示,许多护士选择用于监测患者的导联在诊断上不如其他可用导联,而且导联放置常常不准确。本文回顾了心电图(ECG)监测的最佳导联,说明了其准确放置方法,并解释了当前实践中存在这种困境的原因。文中讨论了与执业护士相关的问题,包括:1)MCL1导联与V1导联一样好吗?2)何时适合用MCL1导联替代V1导联?3)电极精确放置在特定解剖位置有多重要?最后提供了一个案例研究,以说明准确监测如何能够防止误诊及由此导致的不恰当治疗。

相似文献

1
Bedside electrocardiogram monitoring.床边心电图监测。
AACN Clin Issues Crit Care Nurs. 1993 Feb;4(1):25-33.
2
Accuracy of bedside electrocardiographic monitoring: a report on current practices of critical care nurses.床边心电图监测的准确性:重症护理护士当前实践报告
Heart Lung. 1991 Nov;20(6):597-607.
3
An introduction to electrocardiogram monitoring.心电图监测简介。
Nurs Crit Care. 2010 Jan-Feb;15(1):34-8. doi: 10.1111/j.1478-5153.2009.00361.x.
4
Bedside electrocardiographic monitoring: state of the art for the 1990s.
Heart Lung. 1991 Nov;20(6):610-23.
5
A comparison between EASI system 12-lead ECGs and standard 12-lead ECGs for improved clinical nursing practice.用于改善临床护理实践的EASI系统12导联心电图与标准12导联心电图的比较。
J Clin Nurs. 2008 Feb;17(3):370-7. doi: 10.1111/j.1365-2702.2007.01935.x.
6
Continuous ST-segment monitoring: raising the bar.
Crit Care Nurs Clin North Am. 2006 Jun;18(2):169-77, ix. doi: 10.1016/j.ccell.2006.01.006.
7
Celebrating the 100th birthday of the electrocardiogram: lessons learned from research in cardiac monitoring.庆祝心电图诞生100周年:心脏监测研究的经验教训。
Am J Crit Care. 2002 Jul;11(4):378-86; quiz 387-8.
8
Standardization of electrode placement for continuous patient monitoring: introduction of an assessment tool to compare proposed electrocardiogram lead configurations.
J Electrocardiol. 2011 Mar-Apr;44(2):115-8. doi: 10.1016/j.jelectrocard.2010.10.031. Epub 2011 Jan 8.
9
Placement of cardiac electrodes: written, simulated, and actual accuracy.心脏电极的放置:书面、模拟和实际准确性。
Am J Crit Care. 1997 Nov;6(6):457-62.
10
Real-time application of continuous 12-lead ST-segment monitoring: 3 case studies.连续12导联ST段监测的实时应用:3个病例研究
Crit Care Nurse. 2000 Apr;20(2):93-9.