Aoki T, Houkin K, Kamiyama H, Iwasaki Y, Abe H, Koiwa M, Kawaguchi S, Kashiwaba T
Department of Neurosurgery, Hokkaido University School of Medicine, Sapporo, Japan.
No To Shinkei. 1993 Jan;45(1):57-62.
The three-dimensional time-of-flight (TOF) magnetic resonance angiograms (MRA) were studied to evaluate its accuracy in the assessment of the intracranial carotid occlusive lesions, collateral circulation and also the patency of extracranial-intracranial (EC/IC) arterial bypass surgery. All occlusive lesions of the intracranial major arteries seen in conventional angiograms were revealed clearly with MRA. However MRA had its practical limitation in the evaluation of the leptomeningeal anastomosis (collateral circulation) probably due to the deterioration of contrast in its slow flow and saturation effect of the magnetization. In addition to that, MRA often exaggerated the severity of the stenotic lesions, mostly in severe cases. The post-operative state of collateral flow and the patency of EC/IC bypass could be evaluated as properly with MRA as with conventional angiography, although MRA was limited in spatial resolution and evaluation of flow direction. In conclusion, MRA was considered t be a reliable non-invasive modality as a screening examination for the evaluation of the carotid occlusive disease and as the follow-up study of the post-operative patients with EC/IC bypass surgery.
研究三维时间飞跃(TOF)磁共振血管造影(MRA)评估颅内颈动脉闭塞性病变、侧支循环以及颅外-颅内(EC/IC)动脉搭桥手术通畅性的准确性。常规血管造影中所见的颅内主要动脉的所有闭塞性病变在MRA中均清晰显示。然而,MRA在评估软脑膜吻合(侧支循环)方面存在实际局限性,这可能是由于其慢血流中对比度降低以及磁化饱和效应所致。除此之外,MRA常常夸大狭窄病变的严重程度,大多在严重病例中。尽管MRA在空间分辨率和血流方向评估方面存在局限性,但MRA对侧支血流的术后状态以及EC/IC搭桥的通畅性评估与常规血管造影一样准确。总之,MRA被认为是一种可靠的非侵入性检查方法,可作为评估颈动脉闭塞性疾病的筛查检查以及EC/IC搭桥手术后患者的随访研究。