Positron emission tomography technologists were monitored with thermoluminescent dosimeters (TLDs) during qualitative and quantitative studies. Doses to technologists during specific tasks were also measured. The technologists received at least twice as much radiation during the quantitative as the qualitative studies. The average dose per study for qualitative studies was 0.017 mSv (1.7 mrem) shallow and 0.014 mSv (1.4 mrem) deep. The average dose per study for the quantitative studies was 0.05 mSv (5 mrem) shallow and 0.04 mSv (4 mrem) deep. The average dose per study was based on the TLD dose accumulated over studies conducted over four 2-mo and one 1-mo intervals. The dose incurred by the technologists each time they drew a radioactive dose was 0.002 mSv (0.2 mrem) shallow and 0.001 mSv (0.1 mrem) deep. The doses received during injection were 0.014 mSv (1.4 mrem) shallow and 0.007 mSv (0.7 mrem) deep. Doses received during blood sampling were 0.016 mSv (1.6 mrem) shallow and 0.014 mSv (1.4 mrem) deep. During quantitative studies, the technologist received a much greater dose than during its qualitative counterpart due to the blood sampling process and increased time in the room with the radioactive patient.
在定性和定量研究过程中,使用热释光剂量计(TLD)对正电子发射断层扫描技术人员进行监测。还测量了技术人员在特定任务期间所接受的剂量。在定量研究中,技术人员接受的辐射量至少是定性研究的两倍。定性研究中每次研究的平均浅部剂量为0.017毫希沃特(1.7毫雷姆),深部剂量为0.014毫希沃特(1.4毫雷姆)。定量研究中每次研究的平均浅部剂量为0.05毫希沃特(5毫雷姆),深部剂量为0.04毫希沃特(4毫雷姆)。每次研究的平均剂量是基于在四个2个月和一个1个月时间段内进行的研究中TLD累积的剂量。技术人员每次抽取放射性剂量时所遭受的剂量浅部为0.002毫希沃特(0.2毫雷姆),深部为0.001毫希沃特(0.1毫雷姆)。注射期间接受的剂量浅部为0.014毫希沃特(1.4毫雷姆),深部为0.007毫希沃特(0.7毫雷姆)。采血期间接受的剂量浅部为0.016毫希沃特(1.6毫雷姆),深部为0.014毫希沃特(1.4毫雷姆)。在定量研究期间,由于采血过程以及与放射性患者在房间内停留时间增加,技术人员接受的剂量比定性研究时大得多。