[Accuracy of measurements of Kontrol 7840, Nellcor N200 and Radiometer OX13 pulse oximeters in infants and young children].

作者信息

Poets C F, Seidenberg J, Wilken M, von der Hardt H

机构信息

Abteilungen für pädiatrische Pneumologie, Medizinische Hochschule, Hannover.

出版信息

Klin Padiatr. 1993 Mar-Apr;205(2):107-10. doi: 10.1055/s-2007-1025207.

DOI:10.1055/s-2007-1025207
PMID:8487476
Abstract

Comparative validation studies of pulse oximeters from different manufacturers have predominantly been performed in adult patients. However, due to differences in the patient-sensor interface, the results from those studies may not be transferable to the paediatric population. We therefore performed 123 simultaneous measurements (37 patients) of transcutaneous O2-saturation (StcO2) from 3 pulse oximeters and compared these with the arterial O2-saturation (SaO2) from a co-oximeter (Radiometer OSM 3). The median age of the 37 patients at the time of study was 2.0 months (range 1 day-5 years), their weight 4.7 kg (0.8-15.0 kg). The mean difference between StcO2 and SaO2 was -0.6% (SD 5.2%) for the Kontron 7840 pulse oximeter, -0.9% (SD 2.3%) for the Nellcor N200, and -1.2% (SD 3.5%) for the Radiometer OXI3 pulse oximeter. The corresponding 95% intervals were -7.4(-) + 9.6%, -5.7(-) + 4.3% and -7.0(-) + 6.3% for the Kontron, Nellcor and Radiometer instrument, respectively. These results demonstrate that neither of the 3 instruments systematically under- or overestimated SaO2. However, there were differences in precision, particularly in the low range of SaO2.

摘要

相似文献

1
[Accuracy of measurements of Kontrol 7840, Nellcor N200 and Radiometer OX13 pulse oximeters in infants and young children].
Klin Padiatr. 1993 Mar-Apr;205(2):107-10. doi: 10.1055/s-2007-1025207.
2
A comparison of two pulse oximeters. Assessment of accuracy at low arterial saturation in paediatric surgical patients.
Anaesthesia. 1988 Feb;43(2):136-40.
3
Pulse oximetry in very low birth weight infants with acute and chronic lung disease.极低出生体重儿急性和慢性肺部疾病的脉搏血氧饱和度测定
Pediatrics. 1987 Apr;79(4):612-7.
4
Pulse oximetry in children with congenital heart disease: effects of cardiopulmonary bypass and cyanosis.先天性心脏病患儿的脉搏血氧饱和度测定:体外循环和发绀的影响
J Intensive Care Med. 2004 Jul-Aug;19(4):229-34. doi: 10.1177/0885066604263819.
5
Pulse oximetry advantages in infants with bronchopulmonary dysplasia.脉搏血氧饱和度测定法在支气管肺发育不良婴儿中的优势。
Pediatrics. 1986 Nov;78(5):844-9.
6
[Reliability and limitations of pulse oximetry in corrective cyanotic heart surgery].[脉搏血氧饱和度仪在矫正性紫绀型心脏手术中的可靠性及局限性]
Anaesthesist. 1989 Jun;38(6):302-8.
7
Simultaneous comparison of three noninvasive oximeters in healthy volunteers.健康志愿者中三种无创血氧饱和度仪的同步比较
Med Instrum. 1987 Jun;21(3):183-8.
8
Pulse oximeter accuracy and precision affected by sensor location in cyanotic children.脉搏血氧仪的准确性和精确性受紫绀型儿童传感器位置的影响。
Pediatr Crit Care Med. 2008 Jul;9(4):393-7. doi: 10.1097/PCC.0b013e3181727967.
9
Pulse oximetry in newborn infants with birth weights of 620 to 4285 grams receiving dopamine and dobutamine.出生体重620至4285克、正在接受多巴胺和多巴酚丁胺治疗的新生儿的脉搏血氧饱和度测定
J Perinatol. 1996 Jan-Feb;16(1):31-4.
10
Accuracy and precision of fourteen pulse oximeters.
Eur Respir J. 1991 Jan;4(1):115-9.

引用本文的文献

1
Detection of hyperoxaemia in neonates: data from three new pulse oximeters.新生儿高氧血症的检测:来自三款新型脉搏血氧仪的数据。
Arch Dis Child Fetal Neonatal Ed. 2002 Nov;87(3):F217-9. doi: 10.1136/fn.87.3.f217.