Suppr超能文献

采用皮脂胶带-色差仪技术评估皮脂排泄动力学。

Kinetics of sebum excretion evaluated by the Sebutape--Chromameter technique.

作者信息

Piérard G E, Piérard-Franchimont C, Kligman A M

机构信息

Department of Dermatopathology, University of Liège, Belgium.

出版信息

Skin Pharmacol. 1993;6(1):38-44. doi: 10.1159/000211083.

Abstract

We present a novel method for studying the changing characteristics of sebum excretion of facial skin over a 3-hour period. Sebum production can be quantified by analysis of the pore patterns formed on a sebum-sensitive tape (Sebutape). We applied the CIE principles of reflectance colorimetry by measuring L*, a* and b* of Sebutapes every 15 min during 3 h of sebum collection. This combined technique yielded valuable new informations on the kinetics of sebum excretion, allowing the distinction between the follicular reservoir effect and the sebum flow.

摘要

我们提出了一种新颖的方法,用于研究面部皮肤在3小时内皮脂分泌的变化特征。皮脂分泌量可通过分析在皮脂敏感胶带(皮脂测试带)上形成的毛孔图案来量化。在3小时的皮脂收集过程中,我们每隔15分钟测量一次皮脂测试带的L*、a和b,应用了CIE反射比色法原理。这种联合技术产生了关于皮脂分泌动力学的有价值的新信息,能够区分毛囊储存效应和皮脂流动。