Suppr超能文献

唐氏综合征患儿的调节功能减退。

Reduced accommodation in children with Down syndrome.

作者信息

Woodhouse J M, Meades J S, Leat S J, Saunders K J

机构信息

Department of Optometry, University of Wales College of Cardiff, United Kingdom.

出版信息

Invest Ophthalmol Vis Sci. 1993 Jun;34(7):2382-7.

PMID:8505220
Abstract

PURPOSE

To examine the accommodative accuracy and amplitude in children with Down syndrome. Accommodation is usually assumed to be good in children and is rarely measured.

METHODS

A dynamic retinoscopy technique was developed that allows rapid and reliable measures of accuracy and amplitude of accommodation in infants and children.

RESULTS

Use of the dynamic technique with a small sample of schoolchildren with Down syndrome shows that 80% have reduced amplitude of accommodation, in comparison to a control group of developmentally normal children.

CONCLUSIONS

Optometric management of children with Down syndrome should include consideration of accommodation.

摘要

目的

研究唐氏综合征患儿的调节准确性和幅度。通常认为儿童的调节功能良好,且很少进行测量。

方法

开发了一种动态检影技术,可快速、可靠地测量婴幼儿和儿童的调节准确性和幅度。

结果

对一小群唐氏综合征学童使用该动态技术的结果显示,与发育正常的儿童对照组相比,80%的唐氏综合征患儿调节幅度降低。

结论

唐氏综合征患儿的验光管理应包括对调节功能的考量。