Abstract

In a prospective study the size of 157 pelvic tumors in 101 patients was measured preoperatively by bimanual palpation and vaginosonography, and the results were compared with measurements made at operation. In 72 uterine and 85 ovarian lesions the Spearman correlation coefficients (rs) between the three maximum diameters at right angles to each other measured at operation and by bimanual palpation ranged from 0.48 to 0.78. The correlation coefficients (rs) between measurements at operation and preoperative vaginosonography ranged from 0.91 to 0.97. The size of small lesions was overestimated by bimanual palpation; 44% of tumors smaller than 5 cm in diameter were only detected by vaginosonography.

摘要

在一项前瞻性研究中,通过双合诊触诊和阴道超声对101例患者的157个盆腔肿瘤进行术前测量,并将结果与手术时的测量结果进行比较。在72例子宫病变和85例卵巢病变中,手术时测量的相互垂直的三个最大直径与双合诊触诊测量的Spearman相关系数(rs)在0.48至0.78之间。手术时测量与术前阴道超声测量的相关系数(rs)在0.91至0.97之间。双合诊触诊高估了小病变的大小;直径小于5 cm的肿瘤中有44%仅通过阴道超声检测到。