Plato P
Am Ind Hyg Assoc J. 1977 Jan;38(1):41-5. doi: 10.1080/0002889778507909.
To determine if ANSI N13.7-1972 is a useful method to test the accuracy of film badge processors to measure radiation doses to workers in the nuclear industry, a set of exposed dose values is compared to several sets of typical, but imaginary, reported dose values. The ANSI Standard is found to be a complex procedure with no direct test for accuracy. Because of these and other limitations of the Standard, it is concluded that ANSI N13.7-1972 is unacceptable for routine testing of film badges.
为了确定美国国家标准学会(ANSI)N13.7 - 1972标准是否是一种用于测试胶片剂量计处理器测量核工业中工人辐射剂量准确性的有效方法,将一组已曝光剂量值与几组典型但虚构的报告剂量值进行了比较。结果发现ANSI标准是一个复杂的程序,没有直接的准确性测试。由于该标准存在这些及其他局限性,得出结论:ANSI N13.7 - 1972不适用于胶片剂量计的常规测试。