Aronson R S, Gelles J M
Circ Res. 1977 May;40(5):517-24. doi: 10.1161/01.res.40.5.517.
We studied the effect of ouabain and other inhibitors of the Na-K pump on the pacemaker current (IK2) in sheep cardiac Purkinje fibers. We found that exposure to ouabain (2 X 10(7) M) caused an apparent decrease in the amplitude of the IK2 activation curve. We also found that a similar effect was caused by exposure to dinitrophenol (DNP) or lithium-substituted Tyrode's solution. Our studies showed that after prolonged (more than 60 minutes) exposure to ouabain a characteristic current noise appeared and IK2 was replaced by an oscillatory inward current (IOS). The apparent threshold for IOS was -50 to -60 mV and the peak amplitude of this current increased with increasing levels of depolarization positive to threshold. These results suggest that (1) the apparent decrease in IK2 may be a consequence of ionic redistribution due to Na-K pump inhibition; (2) cardiac glycosides cause abnormal impulse generation by an ionic mechanism separate from IK2 and involving IOS.
我们研究了哇巴因及其他钠钾泵抑制剂对绵羊心脏浦肯野纤维起搏电流(IK2)的影响。我们发现,暴露于哇巴因(2×10⁻⁷ M)会导致IK2激活曲线的幅度明显降低。我们还发现,暴露于二硝基酚(DNP)或锂替代的台氏液也会产生类似的效果。我们的研究表明,在长时间(超过60分钟)暴露于哇巴因后,会出现特征性的电流噪声,并且IK2被振荡性内向电流(IOS)所取代。IOS的明显阈值为-50至-60 mV,并且该电流的峰值幅度随着去极化水平高于阈值的增加而增加。这些结果表明:(1)IK2的明显降低可能是由于钠钾泵抑制导致离子重新分布的结果;(2)强心苷通过与IK2不同且涉及IOS的离子机制引起异常冲动的产生。