Vallittu P K, Kokkonen M
Department of Prosthetics and Stomatognathic Physiology, University of Kuopio, Faculty of Dentistry, Finland.
J Prosthet Dent. 1995 Oct;74(4):412-9. doi: 10.1016/s0022-3913(05)80384-1.
The aim of this study was to determine the fatigue resistance of the cast clasps of removable partial dentures. The different commercial types of metals used included five cobalt-chromium alloys, pure titanium, one titanium alloy (Ti-6A1-4V) and one gold alloy (type IV) that was either unhardened or age-hardened (n = 5 per group). The test method used was a constant-deflection fatigue test in which the force required to deflect the clasp for 0.6 mm and the number of loading cycles required to fracture the clasp were determined. The fatigue fracture surface of the clasps was examined with a scanning electron microscope. The results revealed that a fatigue fracture occurred in the cobalt-chromium clasp after approximately 25,000 loading cycles, in the pure titanium clasps after 4500 loading cycles, in the titanium alloy clasp after 20,000 loading cycles, and in the gold alloy clasp after 21,000 loading cycles. The means differed significantly (p < 0.001). Activation of the clasp by bending it 0.5 mm increased the fatigue resistance of the cobalt-chromium alloy and gold alloy clasps but decreased the fatigue resistance of both pure titanium and titanium alloy clasps (p < 0.005). The results of this study suggest that significant differences exist in the fatigue resistance of removable denture clasps made from different commercial cast metals, which may cause loss of retention of the removable partial denture and clasp failures.
本研究的目的是确定可摘局部义齿铸造卡环的抗疲劳性。所使用的不同商业类型的金属包括五种钴铬合金、纯钛、一种钛合金(Ti-6A1-4V)和一种未硬化或时效硬化的金合金(IV型)(每组n = 5)。所采用的测试方法是恒定挠度疲劳试验,其中测定使卡环挠曲0.6 mm所需的力以及使卡环断裂所需的加载循环次数。用扫描电子显微镜检查卡环的疲劳断裂表面。结果显示,钴铬合金卡环在大约25,000次加载循环后发生疲劳断裂,纯钛卡环在4500次加载循环后发生疲劳断裂,钛合金卡环在20,000次加载循环后发生疲劳断裂,金合金卡环在21,000次加载循环后发生疲劳断裂。均值差异显著(p < 0.001)。将卡环弯曲0.5 mm激活可提高钴铬合金和金合金卡环的抗疲劳性,但会降低纯钛和钛合金卡环的抗疲劳性(p < 0.005)。本研究结果表明,由不同商业铸造金属制成的可摘义齿卡环在抗疲劳性方面存在显著差异,这可能导致可摘局部义齿固位丧失和卡环失效。