Aldroubi A, Zakharov S F, Chrambach A
National Center for Research Resources, National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, Maryland 20892-1855, USA.
Appl Theor Electrophor. 1995;5(1):31-4.
The commercial automated gel electrophoresis apparatus (HPGE-1000 of LabIntelligence, Menlo Park, CA) allows one to recover the material migrating and visualized as a fluorescent-labeled band by electrophoresis into a collection cup located above the band at a right angle to the orientation of the separation path. The degree of recovery is a function of sample load (peak area), electrophoresis time at constant field strength, the mobility of the material and band width. Neglecting the latter, recovery of several SDS-proteins was measured as a function of the first three parameters. These measurements were used as a data base for a computer program capable of predicting, by interpolation of the experimental values, the time of electrophoresis needed to obtain a specified degree of recovery, or the degree of recovery obtained after a desired time of electrophoresis into the collection cup.
商用自动凝胶电泳仪(加利福尼亚州门洛帕克市LabIntelligence公司的HPGE - 1000)能使迁移并以荧光标记条带形式可视化的物质,通过电泳回收至位于条带上方且与分离路径方向成直角的收集杯中。回收程度是样品上样量(峰面积)、恒定场强下的电泳时间、物质迁移率和条带宽度的函数。忽略条带宽度,测量了几种SDS蛋白的回收情况与前三个参数的关系。这些测量结果用作计算机程序的数据库,该程序能够通过对实验值进行插值来预测获得特定回收程度所需的电泳时间,或在向收集杯中进行所需电泳时间后获得的回收程度。