Suppr超能文献

生物电阻抗光谱法与多频生物电阻抗分析在评估外科手术患者细胞外液和总体液中的比较

Comparison of bio-impedance spectroscopy and multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients.

作者信息

Hannan W J, Cowen S J, Plester C E, Fearon K C, deBeau A

机构信息

Department of Medical Physics and Medical Engineering, Western General Hospital, Edinburgh, U.K.

出版信息

Clin Sci (Lond). 1995 Dec;89(6):651-8. doi: 10.1042/cs0890651.

Abstract
  1. Measurements of extracellular and total body water provide useful information on the nutritional status of surgical patients and may be estimated from whole-body bio-impedance measurements at different frequencies. 2. Resistance and reactance were measured at 50 frequencies from 5kHz to 1MHz in 29 surgical patients (17 males, 12 females) with a wide range of extracellular to total body water ratios. 3. A fit to the spectrum of reactance versus resistance data gave predicted resistances at frequencies zero and infinity. Values of extracellular and total body water determined by this bio-impedance spectroscopy technique were regressed against values obtained from radioisotope dilution. The standard errors of the estimate were 1.8931 and 3.2591 respectively. 4. Resistance indices (height2/resistance) at selected frequencies gave the highest correlations with extracellular and total body water at 5kHz and 200kHz respectively, and prediction equations derived from multiple stepwise regressions also showed these to be the optimum frequencies. The standard errors of the estimate for this multi-frequency bio-impedance analysis method were 1.9371 and 2.6061 for extracellular and total body water respectively. 5. To assess the ability of the two methods to measure changes in extracellular and total body water, reproducibility was assessed from repeat measurements 10 min apart in a subgroup of 15 patients. Bio-impedance spectroscopy gave mean coefficients of variation for extracellular and total body water of 0.9% and 3.0% respectively. For multi-frequency bio-impedance analysis the corresponding coefficients of variation were 0.9% and 0.6%. 6. It is concluded that a simple impedance analyser operating at only two frequencies compares favourably with the more complex spectroscopy technique for the determination of extracellular and total body water in surgical patients.
摘要
  1. 细胞外液和总体液量的测量可为外科手术患者的营养状况提供有用信息,并且可以通过不同频率下的全身生物电阻抗测量来估算。2. 对29例外科手术患者(17例男性,12例女性)进行了测量,这些患者的细胞外液与总体液的比例范围很广,测量了其在5kHz至1MHz的50个频率下的电阻和电抗。3. 对电抗与电阻数据的频谱进行拟合,得出频率为零和无穷大时的预测电阻。通过这种生物电阻抗光谱技术测定的细胞外液和总体液量值与放射性同位素稀释法获得的值进行回归分析。估计的标准误差分别为1.8931和3.2591。4. 选定频率下的电阻指数(身高²/电阻)分别在5kHz和200kHz时与细胞外液和总体液具有最高的相关性,并且通过多元逐步回归得出的预测方程也表明这两个频率是最佳频率。这种多频率生物电阻抗分析方法对细胞外液和总体液估计的标准误差分别为1.9371和2.6061。5. 为了评估这两种方法测量细胞外液和总体液变化量的能力,对15例患者的一个亚组进行了间隔10分钟的重复测量,以评估其可重复性。生物电阻抗光谱法得出细胞外液和总体液的平均变异系数分别为0.9%和3.0%。对于多频率生物电阻抗分析,相应的变异系数分别为0.9%和0.6%。6. 得出的结论是,对于外科手术患者细胞外液和总体液量的测定,仅在两个频率下运行的简单阻抗分析仪与更复杂的光谱技术相比具有优势。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验