Suppr超能文献

Experimental tracheal replacement using the esophagus and an expandable metallic stent.

作者信息

Kato R, Eguchi K, Izumi Y, Kakizaki T, Hangai N, Sawafuji M, Yamamoto T, Kawamura M, Kikuchi K, Kobayashi K

机构信息

Department of Surgery, School of Medicine, Keio University, Tokyo, Japan.

出版信息

Surg Today. 1995;25(9):806-10. doi: 10.1007/BF00311457.

Abstract

An experimental study was conducted to investigate whether a segment of autogenous esophagus with its lumen supported by an expandable metallic stent (EMS) could be successfully used as a tracheal substitute. Seven rings of the cervical trachea were circumferentially removed and reconstructed by interposing a pedicled segment of the esophagus with an EMS in six mongrel dogs. The interposed esophagus was observed endoscopically at various stages after the operation. By 1 month, the EMS was found to be buried under the esophageal mucosa, and the lumen was patent. The dogs died 5, 17, 61, 92, 210, and 478 days after the operation, but the cause of death could not be determined by postmortem examination and no respiratory tract complications were detected. The results of this study indicated that a segment of the esophagus with its lumen supported by an EMS could work as a reliable tracheal substitute, though its practical use is not clinically feasible. Nevertheless, we conclude that some autogenous material other than the esophagus with its lumen supported by an EMS could provide a feasible method for tracheal replacement.