In a multicentric study involving 4 European cochlear implant centers, the speech perception abilities of 20 native German-speaking individuals implanted with the Nucleus 22 Channel Cochlear Implant System when using a new spectral peak (SPEAK) speech coding strategy were investigated. This strategy continuously analyzes the speech signal using 20 digital programmable bandpass filters and presents up to 10 spectral maxima to the 22 implanted electrodes. Each subject's performance on a variety of auditory perceptual tasks was evaluated with the experimental encoder (SPEAK), relative to his or her performance in a reference condition. An ABAB experimental design was used whereby each strategy was reversed and replicated. The reference levels of auditory performance were established using the multipeak (MPEAK) speech-processing strategy of the Nucleus speech processor. Only subjects who achieved open-set monosyllable word recognition in the reference condition were included in this study. Significant differences in group mean scores for most speech recognition subtests were obtained for the SPEAK versus the MPEAK strategy. The largest overall improvements were observed for the sentence tests under noisy conditions.
在一项涉及4个欧洲人工耳蜗植入中心的多中心研究中,对20名使用新型频谱峰值(SPEAK)言语编码策略植入Nucleus 22通道人工耳蜗系统的德语母语者的言语感知能力进行了研究。该策略使用20个数字可编程带通滤波器持续分析言语信号,并向22个植入电极呈现多达10个频谱最大值。使用实验编码器(SPEAK)评估每个受试者在各种听觉感知任务上的表现,并与他们在参考条件下的表现进行比较。采用ABAB实验设计,每种策略都进行了反转和重复。使用Nucleus言语处理器的多峰值(MPEAK)言语处理策略确定听觉性能的参考水平。本研究仅纳入在参考条件下实现开放式单音节词识别的受试者。对于SPEAK与MPEAK策略,大多数言语识别子测试的组平均分数存在显著差异。在噪声条件下的句子测试中观察到了最大的总体改善。