Okita Y, Takamoto S, Ando M, Morota T, Kawashima Y
Department of Cardiovascular Surgery, National Cardiovascular Center, Osaka, Japan.
J Card Surg. 1995 Nov;10(6):699-702. doi: 10.1111/j.1540-8191.1995.tb00660.x.
A technique of using a triple-lumen balloon catheter for occlusion of the ascending aorta in patients with distal aortic arch aneurysm during open proximal anastomosis utilizing hypothermic retrograde cerebral circulation technique through left thoracotomy was described. The balloon greatly facilitated (1) occlusion of the ascending aorta without cross clamping, (2) delivery of cardioplegic solution, (3) suctioning blood pooled in the aortic arch, and (4) prevention of entrance of debris into the left ventricle or coronary arteries.
描述了一种在通过左胸切口利用低温逆行脑循环技术进行近端开放吻合术时,使用三腔球囊导管阻塞远端主动脉弓瘤患者升主动脉的技术。该球囊极大地促进了:(1)在不进行交叉夹闭的情况下阻塞升主动脉;(2)输送心脏停搏液;(3)抽吸积聚在主动脉弓中的血液;(4)防止碎片进入左心室或冠状动脉。