Suppr超能文献

心肌灌注的数字血管造影脉冲响应分析:心率和血压变化对正常犬冠状动脉循环中微循环通过时间测量的影响。

Digital angiographic impulse response analysis of myocardial perfusion: influence of heart rate and blood pressure changes on microcirculatory transit time measurement in the normal canine coronary circulation.

作者信息

Solzbach U, Liao J, Whiting J S, Eigler N L

机构信息

Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, California 90048, USA.

出版信息

Comput Biomed Res. 1995 Oct;28(5):371-92. doi: 10.1006/cbmr.1995.1025.

Abstract

The study describes the effect of acute changes in aortic blood pressure and heart rate in the intact normal canine coronary circulation on digital angiographic measurements of the mean transit time of the microcirculation compartment and on direct flow meter measurement of resting and maximal hyperemic coronary blood flow. The mean transit time of the radiographic contrast material through the normal coronary circulation was calculated in 20 dogs by the impulse response analysis from serial digital coronary angiograms under systematically changed blood pressure and heart rate conditions. The mean aortic blood pressure (MAP) was controlled by the inflation of a balloon in the descending aorta (70-150 mmHg). The heart rate was altered by atrial pacing (90, 120, and 150/min). The mean transit times (T mu) of contrast material across the myocardial microcirculation which had been recently shown to correlate with coronary flow reserve (CFR) in stenosed arteries in the canine model were calculated under resting and hyperemic flow conditions from 428 selective coronary angiograms after a hand-injected contrast bolus, T mu was found to be heart rate independent. T mu-1 was linearly correlated with MAP (r = 0.7). There was no difference in T mu under resting and hyperemic flow conditions at comparable MAP. The corresponding distribution volume (V mu) of the microcirculation was calculated as the product of the mean transit time T mu and the measured coronary blood flow. Under resting flow conditions, V mu decreased with rising MAP. Furthermore, V mu increased with rising heart rate, V mu was constant during blood pressure or heart rate changes under hyperemic flow conditions. The data suggest that CFR whether by direct measurements of flow or by radiographic assessment of contrast material kinetics should be standardized with respect to hemodynamic conditions of heart rate and MAP.

摘要

该研究描述了在完整正常犬冠状动脉循环中,主动脉血压和心率的急性变化对微循环区平均通过时间的数字血管造影测量以及静息和最大充血状态下冠状动脉血流的直接流量计测量的影响。通过在系统改变血压和心率条件下,对20只犬的系列数字冠状动脉造影进行脉冲响应分析,计算了造影剂在正常冠状动脉循环中的平均通过时间。通过在降主动脉中充气球囊来控制平均主动脉血压(MAP)(70 - 150 mmHg)。通过心房起搏改变心率(90、120和150次/分钟)。在静息和充血血流条件下,从428次手动注射造影剂团注后的选择性冠状动脉造影中计算了造影剂穿过心肌微循环的平均通过时间(Tμ),最近已证明在犬模型中该时间与狭窄动脉中的冠状动脉血流储备(CFR)相关。发现Tμ与心率无关。Tμ的倒数与MAP呈线性相关(r = 0.7)。在可比的MAP下,静息和充血血流条件下的Tμ没有差异。微循环的相应分布容积(Vμ)通过平均通过时间Tμ与测量的冠状动脉血流的乘积来计算。在静息血流条件下,Vμ随MAP升高而降低。此外,Vμ随心率升高而增加,在充血血流条件下,血压或心率变化时Vμ保持恒定。数据表明,无论是通过直接测量血流还是通过造影剂动力学的影像学评估来计算CFR,都应根据心率和MAP的血流动力学条件进行标准化。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验