Suppr超能文献

Digital angiographic impulse response analysis of regional myocardial perfusion. Estimation of coronary flow, flow reserve, and distribution volume by compartmental transit time measurement in a canine model.

作者信息

Eigler N L, Schühlen H, Whiting J S, Pfaff J M, Zeiher A, Gu S

机构信息

Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, Calif. 90048.

出版信息

Circ Res. 1991 Mar;68(3):870-80. doi: 10.1161/01.res.68.3.870.

Abstract

A system impulse response function that describes the kinetics of radiographic contrast material transit through the coronary circulation was calculated from 175 selective digital angiograms of normal and stenotic arteries in 10 dogs during rest and hyperemia. The goal of the study was to determine if the flow and distribution volume characteristics of the epicardial coronary arteries and the myocardial microcirculation could be stimulated by specific mathematical compartments of a lagged normal density model impulse response function in which the flow/distribution volume ratio is the inverse of the mean transit time. The arterial compartment mean transit time correlated with flow (r = 0.75); however, the correlation was significantly improved in individual dogs (r = 0.83 +/- 0.13; p less than 0.005) and was highly dependent on the length of the conduit vessel. The microcirculation compartment mean transit time was distributed as two populations with respect to flow. There was a linear correlation during hyperemia (r = 0.87) and a nonlinear relation during rest, which was characteristic of an autoregulating system. Resting values of microcirculation compartment mean transit time correlated with coronary flow reserve (r = 0.84) and differed significantly between vessels that were normal and those with subcritical stenosis, critical stenosis, or total occlusion (p less than 0.01 for all comparisons). The estimated microcirculation compartment distribution volume increased from a minimum of 4.0 +/- 1.5 ml/100 g myocardium in normal vessels with resting flow to 11.2 +/- 3.5 ml/100 g during hyperemia. These data suggest that the model compartments functionally describe the physiological behavior of their anatomic analogues and permit the quantification of microcirculatory autoregulation from a single measurement at rest without provoking hyperemia.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验