Frahm C, Gehl H B, Weiss H D, Rossberg W A
Institut für Radiologie, Medizinischen Universität Lübeck.
Rofo. 1996 Jan;164(1):62-7. doi: 10.1055/s-2007-1015609.
Due to high soft-tissue contrast and multiplanar imaging capabilities MRI is an interesting modality to perform image-guided biopsies. We checked on the feasibility of MR-guided core biopsies of abdominal masses with an open low-field scanner (0.2 Tesla; vertical field axis).
9 patients underwent MR-guided biopsies of abdominal target lesions (6 focal liver lesions, two adrenal masses, one pelvic mass). Different MR-compatible core biopsy instruments were used (needle diameters 14G-18G). MR scans during the procedures were obtained applying T1-weighted gradient echo sequences suitable for breath-hold imaging.
In each case, needle guidance was reliable, so that the biopsy instrument could be positioned correctly. Multiplanar imaging capabilities enabled even angled approaches to upper abdominal masses to be realized safely. The combination of magnet design and table design offered suitable access to the patient.
Using an open low-field scanner, MR-guided core biopsies of abdominal masses are practicable.
由于磁共振成像(MRI)具有高软组织对比度和多平面成像能力,因此它是一种用于进行图像引导活检的有趣方式。我们检查了使用开放式低场扫描仪(0.2特斯拉;垂直场轴)对腹部肿块进行磁共振引导的粗针活检的可行性。
9例患者接受了腹部目标病变的磁共振引导活检(6例肝脏局灶性病变、2例肾上腺肿块、1例盆腔肿块)。使用了不同的磁共振兼容粗针活检器械(针直径14G - 18G)。在操作过程中,通过应用适用于屏气成像的T1加权梯度回波序列获得磁共振扫描图像。
在每种情况下,针的引导都是可靠的,因此活检器械能够正确定位。多平面成像能力使得对上腹部肿块进行成角度进针的方法也能安全实现。磁体设计和检查台设计的结合为患者提供了合适的进针途径。
使用开放式低场扫描仪,对腹部肿块进行磁共振引导的粗针活检是可行的。