Suppr超能文献

尿流率测量的可重复性:多沙唑嗪治疗良性前列腺增生症双盲、安慰剂对照研究中的经验

Reproducibility of uroflow measurement: experience during a double-blind, placebo-controlled study of doxazosin in benign prostatic hyperplasia.

作者信息

Feneley M R, Dunsmuir W D, Pearce J, Kirby R S

机构信息

Department of Urology, Royal Hospitals NHS Trust, St Bartholomew's Hospital, London, United Kingdom.

出版信息

Urology. 1996 May;47(5):658-63. doi: 10.1016/s0090-4295(96)00014-3.

Abstract

OBJECTIVES

To evaluate the interindividual and intraindividual variation of uroflow measurements in men with benign prostatic hyperplasia (BPH).

METHODS

A total of 147 men with clinical evidence of BPH underwent two uroflow measurements at each of two screening visits prior to recruitment into a placebo-controlled study of doxazosin in the treatment of BPH. The maximum and mean flow rates were determined on each occasion. Differences in the mean value of both parameters for the cohort were examined. The intraindividual variability was evaluated using intraclass correlation coefficients and differences in maximum uroflow at each visit were examined.

RESULTS

Uroflow measurements for the cohort were reproducible and there was no clinically significant difference in maximum and mean flow rate on each occasion. However, the intraclass correlation coefficients for the mean and maximum flow rate varied between 0.70 and 0.82, indicating that intraindividual variation accounted for a substantial component of the total variation in uroflow observed among these patients. For many individuals, test-retest differences were clinically relevant.

CONCLUSIONS

For a group of patients, maximum and mean uroflow measurements are reproducible. However, for an individual, these parameters are subject to clinically significant variation and a single measurement may not be representative. This may be important when considering the need for therapeutic intervention.

摘要

目的

评估良性前列腺增生(BPH)男性患者尿流率测量的个体间和个体内差异。

方法

共有147名有BPH临床证据的男性在入选多沙唑嗪治疗BPH的安慰剂对照研究之前,于两次筛查访视时分别进行了两次尿流率测量。每次测量均测定最大尿流率和平均尿流率。检查该队列中两个参数平均值的差异。使用组内相关系数评估个体内变异性,并检查每次访视时最大尿流率的差异。

结果

该队列的尿流率测量具有可重复性,每次测量的最大尿流率和平均尿流率均无临床显著差异。然而,平均尿流率和最大尿流率的组内相关系数在0.70至0.82之间变化,表明个体内差异占这些患者观察到的尿流总变异的很大一部分。对于许多个体而言,重测差异具有临床相关性。

结论

对于一组患者,最大尿流率和平均尿流率测量具有可重复性。然而,对于个体而言,这些参数存在临床显著变异,单次测量可能不具有代表性。在考虑治疗干预需求时,这可能很重要。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验