Florakis G J, Jewelewicz D A, Fan N I, Trokel S L
Edward S. Harkness Eye Institute, Columbia University, New York, NY, USA.
J Refract Surg. 1996 Feb;12(2):S311-2. doi: 10.3928/1081-597X-19960201-30.
We previously described a simple test which evaluates image degradation in post-excimer laser (PRK) patients under scotopic conditions. After refractive surgery, corneal haze, ablation zone decentration, ablation zone/pupillary diameter disparity, and under-correction each result in a characteristic pattern on the Night Vision Recording Chart.
Using the same method, further studies evaluated night vision image degradation in 118 un-operated emmetropic, myopic, hyperopic, and astigmatic eyes and in 26 contact lens wearers.
Scotopic image degradation increases with myopic refractive error, image displacement increases with astigmatism, and contact lens wearers have more image degradation that with spectacle correction.
Our Night Vision Recording Chart offers a simple, reproducible method to characterize image degradation under scotopic conditions.