van Damme W, Kosmann P, Wackenheim C
Neuroradiology. 1977 May 31;13(3):139-40. doi: 10.1007/BF00626275.
A standardized method for the CT exploration of the orbital region has been searched for. This method makes it possible to visualize the entire orbital region with a minimum of 4 tomographic scans, each section 6 mm thick. The reference line chosen for this exploration is parallel to the optic nerve and joins the projection of the inferior border of the orbit on the lateral view with the upper border of the ear to the scalp. After each tomographic scan the patient is moved so that the new scanning line is still parallel to the reference line but distant by 9 mm from the previous one.
人们一直在寻找一种用于眼眶区域CT扫描的标准化方法。该方法通过最少4次断层扫描即可实现对整个眼眶区域的可视化,每次扫描层厚6毫米。此次扫描所选用的参考线与视神经平行,并且在侧视图中将眼眶下缘的投影与耳上缘至头皮的连线相连。每次断层扫描后移动患者,使新的扫描线仍与参考线平行,但与前一条扫描线相距9毫米。